Forum: General Discussion 02-03-2014, 08:33 PM
Replies: 75
Views: 8,242
Posted By Gene S.
Congratulations! Its a great accomplishment and...

Congratulations! Its a great accomplishment and will serve you and your family well. When I got my first masters license I felt like I could do anything- 8 licenses later and I still do!
Forum: Plumbing 02-02-2014, 08:30 AM
Replies: 39
Views: 6,763
Posted By Gene S.
Damn auto correct- should say "common"...

Damn auto correct- should say "common" vents
Forum: Plumbing 02-02-2014, 08:28 AM
Replies: 39
Views: 6,763
Posted By Gene S.
Actually, it does work. The problem you may run...

Actually, it does work. The problem you may run into is you could restrict the free air flow in the vent and cause the same problem- a blocked vent- just from a different source. A lot of times in a...
Forum: General Discussion 01-25-2014, 01:58 PM
Replies: 92
Views: 12,957
Posted By Gene S.
I love those shows! All of them. They give me a...

I love those shows! All of them. They give me a good laugh and I make a game of trying topic out all the f-ups the average ho might not pick up on. I really do like the ones where they pick some one...
Forum: Plumbing 01-24-2014, 10:11 PM
Replies: 39
Views: 6,763
Posted By Gene S.
You can buy the heat tape with a thermostatically...

You can buy the heat tape with a thermostatically controlled switch on it. True enough it needs to be checked once in awhile to make sure its plugged in and the gfci isn't tripped. We see them a lot...
Forum: Kitchens & Baths 01-24-2014, 05:19 PM
Replies: 13
Views: 3,055
Posted By Gene S.
Go for it- I don't see where it would be a...

Go for it- I don't see where it would be a violation, not in my neck of the woods anyway.
Forum: Plumbing 01-23-2014, 11:14 PM
Replies: 11
Views: 1,695
Posted By Gene S.
do yourself a favor and call in a licensed...

do yourself a favor and call in a licensed plumber to make the repair. If its not done right it could come back to bite you. Will probably take a decent plumber less than 30 minuets for a solid,...
Forum: Plumbing 01-23-2014, 02:38 PM
Replies: 39
Views: 6,763
Posted By Gene S.
Cool That smells kinda fishy

That smells kinda fishy
Forum: Plumbing 01-23-2014, 02:31 PM
Replies: 39
Views: 6,763
Posted By Gene S.
All my licenses are in Buffalo and the...

All my licenses are in Buffalo and the surrounding areas. Not Rochester but Rochester falls under the same NYS plumbing code which is based on the IPC.
Forum: Plumbing 01-23-2014, 01:10 PM
Replies: 39
Views: 6,763
Posted By Gene S.
The NYS Plumbing code book calls for all vents...

The NYS Plumbing code book calls for all vents that go outside the roof be 3" but here in WNY we see a lot of smaller vents thru roofs as long as the stack vent is 3".
Forum: Plumbing 01-23-2014, 01:04 PM
Replies: 39
Views: 6,763
Posted By Gene S.
The 1 1/2" vent should be cut back at least 12"...

The 1 1/2" vent should be cut back at least 12" below the roof deck and then reducer then go at least 18" above the roof with 3" (Section 904 in the IPC). The 2 90's wont work and will actually...
Forum: Plumbing 01-23-2014, 12:15 PM
Replies: 39
Views: 6,763
Posted By Gene S.
Its called "frost-over" here. Code requires at...

Its called "frost-over" here. Code requires at least on of the vents thru the roof be at least 3" diameter to help combat this. I have seen it happen to 3" pipe but not very often. Check yer size
Forum: HVAC 01-22-2014, 10:10 PM
Replies: 37
Views: 27,691
Posted By Gene S.
How many guys will be on job site? How many days...

How many guys will be on job site? How many days will I take to complete job? Hit your local Angies List and BBB. How many service techs does the company have on call on any given night? What types...
Forum: Plumbing 01-22-2014, 09:11 PM
Replies: 1
Views: 2,364
Posted By Gene S.
The 1 1/2" branch vent is fine. The vanity should...

The 1 1/2" branch vent is fine. The vanity should vent the way you have the red dotted lines.
Forum: HVAC 01-22-2014, 12:18 PM
Replies: 72
Views: 16,033
Posted By Gene S.
Also consider most HVAC contractors I know have...

Also consider most HVAC contractors I know have been totally screwed over by GC at least once so the price goes up with the PIA factor. Here the 13seer 2 ton condenser, coil, line set, disconnect,...
Forum: Plumbing 01-22-2014, 11:56 AM
Replies: 53
Views: 5,136
Posted By Gene S.
I'm a plumber. A few weeks ago I had a call after...

I'm a plumber. A few weeks ago I had a call after midnight from a lady who had water leaking into her basement in a two family (upper/lower) home but didn't know where it was coming from. The water...
Showing results 1 to 16 of 16

 
Forum Jump

Join Now... It's Fast and FREE!

I am a professional contractor
I am a DIY Homeowner
Drywall Talk is for
PROFESSIONAL CONTRACTORS ONLY!

At DrywallTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?