Forum: HVAC 08-05-2012, 09:21 PM
Replies: 6
Views: 8,588
Posted By NickTech
spectroline makes a good dye remover for their...

spectroline makes a good dye remover for their dyes called "Glow Away". works pretty good.
Forum: HVAC 11-24-2010, 09:00 PM
Replies: 35
Views: 4,025
Posted By NickTech
uggh, yer right. i just breezed through it. its...

uggh, yer right. i just breezed through it. its the Rc. i wish i was older to blame it on old age.:no:
Forum: HVAC 11-24-2010, 01:35 PM
Replies: 35
Views: 4,025
Posted By NickTech
well after all the banter, here is a link to...

well after all the banter, here is a link to honeywell with the wiring scheme. the R terminal transformer is the transformer the common is to be taken from, ensure the jumper to there rc and r...
Forum: HVAC 11-24-2010, 10:07 AM
Replies: 5
Views: 1,674
Posted By NickTech
how does the domestic hot water get heated? i'm...

how does the domestic hot water get heated? i'm assuming its electrical. a hvac tech can plumb a heating loop from your water heater to a forced convection radiator in the wall. looks like a recessed...
Forum: HVAC 11-19-2010, 11:01 AM
Replies: 35
Views: 4,025
Posted By NickTech
if the unit requires its own 24v circuit than it...

if the unit requires its own 24v circuit than it will take it from either rc or rh. its important to know from where because thats where the common will be taken from. it should be in the...
Forum: HVAC 11-19-2010, 10:28 AM
Replies: 10
Views: 11,137
Posted By NickTech
try burying an 8in pvc line and run a 6 in metal...

try burying an 8in pvc line and run a 6 in metal inside. it would give you a 1in gap around that would improve the r value, or a blow in foam can be used. a blower can be used inside the home to pull...
Forum: HVAC 11-10-2010, 11:26 AM
Replies: 20
Views: 2,759
Posted By NickTech
the internet is a wonderful tool. late 15c.,...

the internet is a wonderful tool.
late 15c., "act of cooling or freezing," from L. refrigerationem "mitigation of heat," especially in sickness, noun of action from refrigerare, from re- "again" +...
Forum: HVAC 11-04-2010, 09:05 AM
Replies: 14
Views: 2,302
Posted By NickTech
at this pace we'll be slinging 300lb ice cakes...

at this pace we'll be slinging 300lb ice cakes door to door. bring back any memories "clover"? ;)
Forum: HVAC 10-27-2010, 09:01 AM
Replies: 7
Views: 3,949
Posted By NickTech
dont pay him to tell you what he thinks it is,...

dont pay him to tell you what he thinks it is, have him earn him money and find out exactly what it is.
and I completely agree with flash!
Forum: HVAC 10-11-2010, 07:46 AM
Replies: 45
Views: 13,547
Posted By NickTech
I started this post some time ago asking offering...

I started this post some time ago asking offering advise for problems out there. I'd like to apologize for not responding to the the questions made shortly after. i was activated to active duty...
Forum: HVAC 09-03-2010, 09:15 AM
Replies: 7
Views: 2,800
Posted By NickTech
thanks man, i was trying to run the acronym thru...

thanks man, i was trying to run the acronym thru my head a hundred times. i can sleep now lol
Forum: HVAC 09-02-2010, 06:10 PM
Replies: 7
Views: 2,800
Posted By NickTech
gene, pleeeeease tell me what GMOD is!

gene, pleeeeease tell me what GMOD is!
Forum: HVAC 08-05-2010, 07:17 AM
Replies: 16
Views: 4,658
Posted By NickTech
my guess is the house is tighter than its ever...

my guess is the house is tighter than its ever been with all the new insulation and the attic isn't breathing. The moisture that used to be vented out thru eaves and what not is now staying put. the...
Forum: HVAC 08-03-2010, 07:30 PM
Replies: 16
Views: 4,658
Posted By NickTech
water might be blowing off the coil onto the...

water might be blowing off the coil onto the inside of the duct causing the problem. are all the seams to the insulation around the duct taped up forming a complete vapor barrier? moisture will find...
Forum: HVAC 08-02-2010, 02:18 PM
Replies: 7
Views: 1,816
Posted By NickTech
I agree, however this question is for the guy...

I agree, however this question is for the guy who's paying the $22 an hr. You need a good pep in your step and a sence of hustle while working, but make sure he's not killing you asking for...
Forum: HVAC 07-27-2010, 07:04 PM
Replies: 9
Views: 3,297
Posted By NickTech
actually a hi pressure switch with manual reset...

actually a hi pressure switch with manual reset is designed for that
Forum: HVAC 07-22-2010, 08:53 PM
Replies: 24
Views: 6,563
Posted By NickTech
so what happened?

so what happened?
Forum: HVAC 07-22-2010, 07:52 PM
Replies: 14
Views: 3,390
Posted By NickTech
The EPA states that a comfort cooling system with...

The EPA states that a comfort cooling system with more than 50 lbs of refrigerant be leak checked when the annual leak rate exceeds 15%. I dont know of any residential systems with more that 20 to 25...
Forum: HVAC 07-08-2010, 09:36 AM
Replies: 24
Views: 6,563
Posted By NickTech
make sure the breakers and fuses being used are...

make sure the breakers and fuses being used are HACR type or time delay type. standard fuses cant tolerate the great inrush current of the compressor at start up and will trip.
Forum: HVAC 07-03-2010, 01:04 PM
Replies: 8
Views: 3,109
Posted By NickTech
honestly, the best way to tackle this is to...

honestly, the best way to tackle this is to recover the refrig. and put in a new valve. Outside of this, there is no bandaid fix that would make for certain a solid repair.
Forum: HVAC 06-28-2010, 10:49 AM
Replies: 16
Views: 6,041
Posted By NickTech
nice!!!

nice!!!
Forum: HVAC 06-28-2010, 06:52 AM
Replies: 16
Views: 6,041
Posted By NickTech
since there was a cap. it's definately single...

since there was a cap. it's definately single phase. If a cap is malfunctioning or ever wired backwards it will cause the motor to run backwards. I've had brand new goodman condensors come with the...
Forum: HVAC 06-28-2010, 06:47 AM
Replies: 13
Views: 3,914
Posted By NickTech
i've always just cut out the fitting and brazed a...

i've always just cut out the fitting and brazed a length of pipe with a schrader valve tapped in. I hate messing with those things. trying to fill em with solder or brazing just over heats everything...
Forum: HVAC 06-24-2010, 12:21 PM
Replies: 10
Views: 2,337
Posted By NickTech
lol

lol
Forum: HVAC 06-08-2010, 11:04 AM
Replies: 6
Views: 2,274
Posted By NickTech
ditto

ditto
Showing results 1 to 25 of 271

 
Forum Jump

Join Now... It's Fast and FREE!

I am a professional contractor
I am a DIY Homeowner
Drywall Talk is for
PROFESSIONAL CONTRACTORS ONLY!

At DrywallTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?