Forum: HVAC 10-20-2014, 08:05 PM
Replies: 23
Views: 8,256
Posted By coolmen
I would check the static pressure of the hvac ...

I would check the static pressure of the hvac system to see if there are major duct problems.
Forum: HVAC 10-20-2014, 07:51 PM
Replies: 5
Views: 2,974
Posted By coolmen
moisture may collect on ceiling

moisture may collect on ceiling
Forum: Drywall 10-20-2013, 10:23 PM
Replies: 6
Views: 1,491
Posted By coolmen
Old ceiling removed

I removed the old 12 inch squares on the ceiling of the living room. That was held on by 1/2" x 2 " wood strips. I removed the wood strips and lost all the insulation .ended up replacing the insu...
Forum: HVAC 04-02-2011, 06:16 PM
Replies: 14
Views: 3,484
Posted By coolmen
anyone hungry for pizza :laughing:

anyone hungry for pizza :laughing:
Forum: HVAC 03-23-2011, 08:59 PM
Replies: 14
Views: 36,910
Posted By coolmen
Im 15 min away from little falls if she is still...

Im 15 min away from little falls if she is still in need of help.
Forum: Plumbing 01-28-2011, 09:56 PM
Replies: 4
Views: 1,819
Posted By coolmen
well pump issues

I went to a house where homeowner has hwh problem.The electric hwh is malfunctioning for some reason with the well pump running.
this pump has a well troll pressure tank wx-202.the pressure was 45...
Forum: HVAC 12-04-2010, 08:48 AM
Replies: 13
Views: 12,029
Posted By coolmen
put the door on and when it fails what does the...

put the door on and when it fails what does the control bord lights code tell you.
take a photo of the unit so we can see install. sounds like pressure switch cutting out gas valve. what size of...
Forum: HVAC 10-20-2010, 04:37 PM
Replies: 3
Views: 1,516
Posted By coolmen
Great stuff! Use it about every day and just...

Great stuff! Use it about every day and just purchased the commercial calc.
Forum: HVAC 10-20-2010, 04:35 PM
Replies: 3
Views: 1,767
Posted By coolmen
system #1 RGRM09EZAJS furnace, coil ...

system #1 RGRM09EZAJS furnace, coil RCFLHM3821cc, condenser RAPM042JEZ

system #2 RGTM06EMAES furnace, coil RCFLHM2417cc, condenser RAPM024JEZ

The ari site ask mfg of coil but does not list...
Forum: HVAC 10-14-2010, 03:00 PM
Replies: 3
Views: 1,767
Posted By coolmen
Ahri #

Have a rheem condenser rapm030-jez and indoor coil rcflhm3617

they make the web site diffacult to input #.
Forum: HVAC 05-08-2010, 08:05 PM
Replies: 7
Views: 2,966
Posted By coolmen
I deal with this sort of thing often when...

I deal with this sort of thing often when troubleshooting a job.
I will first do a load calculation manual J for each floor to verify size heat and cooling. I find that the smaller furnace is most...
Forum: HVAC 03-15-2010, 04:13 PM
Replies: 1
Views: 3,336
Posted By coolmen
To much trouble for just 2 " :whistling

To much trouble for just 2 "
:whistling
Forum: HVAC 01-31-2010, 04:31 PM
Replies: 44
Views: 7,161
Posted By coolmen
the ceiling grid is not installed for you to lean...

the ceiling grid is not installed for you to lean on .
you could have killed yourself or even hurt someone else for that matter.
Id be pissed to.
hell Id lay you off after a while.
Forum: HVAC 11-14-2009, 09:40 PM
Replies: 4
Views: 1,921
Posted By coolmen
I am replacing a old oil boiler with a gas...

I am replacing a old oil boiler with a gas tankless unit.water
i performed a manual J load calc. 80,000 btu heat loss.I measured 5 cast iron rads 6 setions on the lower level and 12 in the wall type...
Forum: Plumbing 11-10-2009, 07:31 PM
Replies: 1
Views: 1,753
Posted By coolmen
flushing out radiators

I am installing a tankless boiler and the house has convectors and radiators.I will flush out the system befor firing up and some one said to install a inline filter. Is this a good idea to protect...
Forum: HVAC 11-05-2009, 07:14 AM
Replies: 4
Views: 1,921
Posted By coolmen
measurment of radiator

Hi
I walked a house late last night measureing the cast iron radiators.
I am measureing so to figure out the EDR so to figure boiler size needed.
The rads are in wall type24x30,20x69,20x55,20x36....
Forum: Plumbing 10-03-2009, 05:25 AM
Replies: 1
Views: 1,801
Posted By coolmen
The job is going very well right now . how ever I...

The job is going very well right now . how ever I cant seem to locate/buy the 008 secondary pump. I do not want to use something differant if possible so to make a better looking job. One supply...
Forum: Plumbing 10-01-2009, 08:50 PM
Replies: 1
Views: 1,801
Posted By coolmen
trinity Ti 100 tankless

I am about to install my first tankless high eff setup.I have some basic questions on the install.I have been certified by Gama and have done plenty of service of boilers in the 20 years of hvac. I...
Forum: HVAC 09-07-2009, 01:52 PM
Replies: 3
Views: 1,872
Posted By coolmen
all codes apply that 1" clearance from bvent to...

all codes apply that 1" clearance from bvent to any cumbustable materials
Forum: HVAC 07-20-2009, 01:18 PM
Replies: 3
Views: 1,609
Posted By coolmen
I will go with gas tight when very busy and hard...

I will go with gas tight when very busy and hard pipe on the slow times.
Hard pipe keeps you working a bit longer.
Forum: HVAC 07-20-2009, 01:11 PM
Replies: 6
Views: 10,575
Posted By coolmen
thats what I was gonna say:))

thats what I was gonna say:))
Forum: HVAC 06-14-2009, 02:33 PM
Replies: 2
Views: 1,753
Posted By coolmen
I resolved the problem. When it was 130* in the...

I resolved the problem. When it was 130* in the attic and the end of the day ,I goofed.

they have some 12 wires comeing out of the A/H.
Forum: HVAC 06-14-2009, 08:07 AM
Replies: 2
Views: 1,753
Posted By coolmen
wirng a goodman A/H

I have a AEPF4260 variable spd unit.
The low Voltage wiring coming out taped says to go to condenser.label R,Y,C
the other harnas says to thermostat R,C,Y1, y/y2,G

I have a single stage...
Forum: HVAC 06-07-2009, 06:09 AM
Replies: 12
Views: 18,665
Posted By coolmen
static pressure test at the system unt will give...

static pressure test at the system unt will give good info.
Forum: HVAC 05-07-2009, 07:30 PM
Replies: 7
Views: 1,879
Posted By coolmen
Columbus is a good 1.30 hours from me. Each way....

Columbus is a good 1.30 hours from me. Each way. To far of a drive
Showing results 1 to 25 of 102

 
Forum Jump

Join Now... It's Fast and FREE!

I am a professional contractor
I am a DIY Homeowner
Drywall Talk is for
PROFESSIONAL CONTRACTORS ONLY!

At DrywallTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?