Number Of Bends In Sanitary Drain Pipe


Hi guys,

A HO wants me to open up an existing L.B. wall and make it a knee wall with posts. Basically a "window" look.

I have a 3" or 4" drain pipe running in the middle of the wall (where I want to open up). Which means re-directing the pipe into a BULK HEAD, then back into the wall, at a different point beside the posts (on either side).

This means 7 90 degree bends between the ceiling of the first floor and the cleanout above the basement slab. I don't know how many times it has bent in the ceiling of the first floor.

45's are possible, it will just increase the size of the bulk-head. I'm at the feasibility stage and promised the HO I would find out if there any issues with this before I start designing this knee wall. At some point my plumber will deal with it but I need to know whether it is even possible.

Any ideas?
Thanks in advance.
Attached Thumbnails
Number of bends in sanitary drain pipe-knee-wall-breakdown.jpg   Number of bends in sanitary drain pipe-proposed-knee-wall.jpg  
__________________
Toronto General Contractor
The foundation stones for a balanced success are honesty, character, integrity, faith, love and loyalty.
-Zig Ziglar
Heritage is offline  

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

   

Advertisement

 

Old 09-17-2012, 01:55 PM   #2
manipulator of wood
 
I Mester's Avatar
 
Trade: general contractor
Join Date: Aug 2011
Location: north jersey
Posts: 835
Rewards Points: 500

Re: Number Of Bends In Sanitary Drain Pipe


have your pl;umber look at it NOW. cant use tight 90 degree bends everywhere. will have to use 45's or sweep 90's

Advertisement

__________________
I just love the smell of sawdust in the morning!
I Mester is offline  
The Following 2 Users Say Thank You to I Mester For This Useful Post:
Heritage (09-18-2012), mehtwo (09-29-2012)
Old 09-17-2012, 02:41 PM   #3
General Contractor
 
greg24k's Avatar
 
Trade: New Home Construction-Additions-Remodeling
Join Date: May 2007
Location: NJ
Posts: 7,487
Rewards Points: 8,076

Re: Number Of Bends In Sanitary Drain Pipe


What you plan to do on the top, after you cut the studs, you will need a header to carry the above load... I think the pipe bends are the least of your problem.
__________________
I never lost a cent on the jobs I didn't get!
greg24k is offline  
Sponsored Links
Advertisement
 
Old 09-17-2012, 05:25 PM   #4
Future Post Deleter...
 
rex's Avatar
 
Trade: Nothing
Join Date: Jul 2007
Location: Nowhere
Posts: 1,895
Rewards Points: 1,092

Re: Number Of Bends In Sanitary Drain Pipe


Long sweep 90's.

The sh!t will be worn out by the time it gets to where its going.
rex is offline  
The Following 5 Users Say Thank You to rex For This Useful Post:
Gary H (09-18-2012), Heritage (09-18-2012), Jaws (09-17-2012), MASTERPLUMB (09-23-2012), mehtwo (09-29-2012)
Old 09-17-2012, 06:55 PM   #5
The Grand Wazoo
 
KillerToiletSpider's Avatar
 
Trade: It blowed up real good!
Join Date: May 2007
Location: Illinois
Posts: 3,945
Rewards Points: 1,924

Re: Number Of Bends In Sanitary Drain Pipe


Quote:
Originally Posted by rex View Post
Long sweep 90's.

The sh!t will be worn out by the time it gets to where its going.
A turd roller coaster.
__________________
I may be going to hell in a bucket, but at least I'm enjoying the ride.
KillerToiletSpider is offline  
The Following 3 Users Say Thank You to KillerToiletSpider For This Useful Post:
MASTERPLUMB (09-23-2012), mehtwo (09-29-2012), plummen (09-19-2012)
Old 09-19-2012, 09:08 PM   #6
Da Grump
 
plummen's Avatar
 
Trade: retired plumbing/electrical/hvac
Join Date: Jan 2010
Location: south of omaha
Posts: 441
Rewards Points: 298

Re: Number Of Bends In Sanitary Drain Pipe


i hope they live next door to a drain cleaner!
Attached Images
 
plummen is offline  
The Following User Says Thank You to plummen For This Useful Post:
MASTERPLUMB (09-23-2012)
Old 09-20-2012, 06:21 PM   #7
Pro
 
catspaw's Avatar
 
Trade: building
Join Date: Oct 2008
Posts: 166
Rewards Points: 150

Re: Number Of Bends In Sanitary Drain Pipe


everytime a turd is flushed it will sound like a pin ball machine in the wall!
catspaw is offline  
The Following 2 Users Say Thank You to catspaw For This Useful Post:
plummen (09-20-2012), sycamorebob (09-23-2012)
Old 09-27-2012, 11:17 PM   #8
jack of all trades
 
one man show's Avatar
 
Trade: general
Join Date: Dec 2010
Posts: 141
Rewards Points: 75

Re: Number Of Bends In Sanitary Drain Pipe


135 dgrees without a cleanout
one man show is offline  
Old 09-28-2012, 11:50 PM   #9
Guy who makes things
 
UALocal1Plumber's Avatar
 
Trade: Plumbing
Join Date: Jun 2009
Location: Queens NY
Posts: 295
Rewards Points: 254

Re: Number Of Bends In Sanitary Drain Pipe


Quote:
Originally Posted by one man show
135 dgrees without a cleanout
Can you source that to a code?
__________________
"To pipe" means to install a plumbing system, not "to plumb". When someone says that they "plumbed the house in" I want to cringe. What you told me is that you held a 6' level against the wall.
UALocal1Plumber is offline  
Old 09-29-2012, 12:42 AM   #10
jack of all trades
 
one man show's Avatar
 
Trade: general
Join Date: Dec 2010
Posts: 141
Rewards Points: 75

Re: Number Of Bends In Sanitary Drain Pipe


707.4 california plumbing code

on a horizontal waste u r allowed up to 135 degrees
next time look it up yourself tough guy

Last edited by one man show; 09-29-2012 at 01:15 AM.
one man show is offline  
Old 09-29-2012, 05:32 AM   #11
Pro
 
Big Shoe's Avatar
 
Trade: Carpentry,drywall,trim. Part time painter.
Join Date: Jun 2008
Location: Florida
Posts: 4,415
Rewards Points: 1,910

Re: Number Of Bends In Sanitary Drain Pipe


Whats below the floor. To redirect the flow in walls below?

When we run into plumbing like that we try to go with other options/designs.

Good luck.
__________________
Expect the Unexpected
Big Shoe is offline  
Old 09-29-2012, 10:35 AM   #12
Life Apprentice
 
mehtwo's Avatar
 
Trade: Plumbing & Carpentry
Join Date: Nov 2010
Location: Southeastern NM
Posts: 1,066
Rewards Points: 558

Re: Number Of Bends In Sanitary Drain Pipe


Quote:
Originally Posted by catspaw View Post
everytime a turd is flushed it will sound like a pin ball machine in the wall!
That's why you insulate the wall.
__________________
Don't make excuses, make it happen!!!!
mehtwo is offline  
Old 09-29-2012, 10:39 AM   #13
Life Apprentice
 
mehtwo's Avatar
 
Trade: Plumbing & Carpentry
Join Date: Nov 2010
Location: Southeastern NM
Posts: 1,066
Rewards Points: 558

Re: Number Of Bends In Sanitary Drain Pipe


Quote:
Originally Posted by Heritage View Post
Hi guys,

A HO wants me to open up an existing L.B. wall and make it a knee wall with posts. Basically a "window" look.

I have a 3" or 4" drain pipe running in the middle of the wall (where I want to open up). Which means re-directing the pipe into a BULK HEAD, then back into the wall, at a different point beside the posts (on either side).

This means 7 90 degree bends between the ceiling of the first floor and the cleanout above the basement slab. I don't know how many times it has bent in the ceiling of the first floor.

45's are possible, it will just increase the size of the bulk-head. I'm at the feasibility stage and promised the HO I would find out if there any issues with this before I start designing this knee wall. At some point my plumber will deal with it but I need to know whether it is even possible.

Any ideas?
Thanks in advance.
Just hang a mirror and both sides of the wall the same size as the proposed opening, MUCH EASIER!

Btw what is that at the bottom of the wall next to the wall receptacle, a register or is it for return air?

I want to see the progress pic of this project.
__________________
Don't make excuses, make it happen!!!!

Last edited by mehtwo; 09-29-2012 at 10:42 AM.
mehtwo is offline  
Old 09-30-2012, 02:25 PM   #14
Guy who makes things
 
UALocal1Plumber's Avatar
 
Trade: Plumbing
Join Date: Jun 2009
Location: Queens NY
Posts: 295
Rewards Points: 254

Re: Number Of Bends In Sanitary Drain Pipe


Quote:
Originally Posted by one man show
707.4 california plumbing code

on a horizontal waste u r allowed up to 135 degrees
next time look it up yourself tough guy
I looked it up myself which is why I couldn't find anything.

It's a good thing I don't live in California.

The NYC code which is based on the ICC states that one cleanout is required every 40 feet of developed length when there are multiple changes of direction. 708.3.3.

Nothing about total degrees of fittings.

Tough guy.

Keith
__________________
"To pipe" means to install a plumbing system, not "to plumb". When someone says that they "plumbed the house in" I want to cringe. What you told me is that you held a 6' level against the wall.
UALocal1Plumber is offline  
Old 09-30-2012, 02:44 PM   #15
jack of all trades
 
one man show's Avatar
 
Trade: general
Join Date: Dec 2010
Posts: 141
Rewards Points: 75

Re: Number Of Bends In Sanitary Drain Pipe


Do u mean IRC ? the ICC is the international code council the governing agency for jurisdictions and inspectors. They dont write the codes. The IRC international residental code states each fitting with a change of direction graeter than 45 degrees in a building sewer, building drain or horizontal waste -where more than one chage of direction occurs in a run only one per 40 feet of developed length.

The uniform plumbing code UPC is what we here in Ca. base the code on and the UPC states every 135 degrees and 100 feet


I looked it up myself which is why I couldn't find anything. REALLY?
just kidding about the tough guy stuff im sure u can plumb circles around me

Steve
one man show is offline  
Old 09-30-2012, 07:54 PM   #16
Life Apprentice
 
mehtwo's Avatar
 
Trade: Plumbing & Carpentry
Join Date: Nov 2010
Location: Southeastern NM
Posts: 1,066
Rewards Points: 558

Re: Number Of Bends In Sanitary Drain Pipe


Quote:
Originally Posted by one man show View Post
Do u mean IRC ? the ICC is the international code council the governing agency for jurisdictions and inspectors. They dont write the codes. The IRC international residental code states each fitting with a change of direction graeter than 45 degrees in a building sewer, building drain or horizontal waste -where more than one chage of direction occurs in a run only one per 40 feet of developed length.

The uniform plumbing code UPC is what we here in Ca. base the code on and the UPC states every 135 degrees and 100 feet


I looked it up myself which is why I couldn't find anything. REALLY?
just kidding about the tough guy stuff im sure u can plumb circles around me

Steve
It could be the IPC(international plumbing code)......
__________________
Don't make excuses, make it happen!!!!

Last edited by mehtwo; 10-05-2012 at 12:59 AM.
mehtwo is offline  
Old 10-03-2012, 01:54 PM   #17
Pro
 
catspaw's Avatar
 
Trade: building
Join Date: Oct 2008
Posts: 166
Rewards Points: 150

Re: Number Of Bends In Sanitary Drain Pipe


Quote:
Originally Posted by one man show View Post
707.4 california plumbing code

on a horizontal waste u r allowed up to 135 degrees
next time look it up yourself tough guy
true statement but it looks like a vertical drain?
catspaw is offline  
Old 11-11-2012, 11:38 AM   #18
Registered User
 
fjeplumbing's Avatar
 
Trade: Plumbing
Join Date: Nov 2012
Location: Los Angeles, California
Posts: 4
Rewards Points: 10

Re: Number Of Bends In Sanitary Drain Pipe


Yup, thats one of the first things we learn as apprentices. a 90 and a 45 or three 45s

Advertisement

fjeplumbing is offline  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Drain Hell darr1 General Discussion 13 07-25-2012 09:40 AM
Drain line Integritybd Construction 2 05-23-2012 02:28 PM
Bathroom sink strainer drain issue with venting stanfordconst Plumbing 1 05-19-2011 06:06 PM
roof drain pipe clogged Grumpy Plumbing 11 09-19-2008 09:00 PM
How to rock around drain pipe that stick out 1/4in from stud? ruskent Drywall 11 04-26-2006 11:02 PM