Lead Shielded Cable.


Anybody ever run across lead shielded cable?

I remember reading about it during my brief stint in the IBEW apprenticship program in the early 70's and I actually came across it ONE time soon after that, installed as underground feeders to a couple of outbuildings on a rural ranch.

I never saw it again or heard anyone on the message boards mention it.

Anyone?
__________________
Just because it's within code doesn't make it safe.

Just because it's against code doesn't make it unsafe.
220/221 is offline  

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

   

Advertisement

 

Old 03-25-2008, 12:57 PM   #2
Service & Repairs
 
Magnettica's Avatar
 
Trade: Electrician
Join Date: Dec 2006
Location: Rahway, New Jersey
Posts: 4,001
Rewards Points: 2,002

Re: Lead Shielded Cable.


Like you, I learned about it once in school. The teacher even brought in a sample, sort of like a show 'n tell. The MI cable was dirty and not very flexible.

Advertisement

Magnettica is offline  
Old 03-25-2008, 01:51 PM   #3
Union Electrician
 
Sparky Joe's Avatar
 
Trade: Inside Wireman
Join Date: Apr 2006
Location: Salt Lake City
Posts: 1,222
Rewards Points: 500

Re: Lead Shielded Cable.


I'm not sure if lead insulated is the same as Mineral Insulated (MI), but we've been installing a lot of MI cable lately being used as snowmelt for light rail platforms. It's a system made by Tyco and pretty pricey from what I heard and pretty fragile from what I've noticed.
If it's kinked it's ruined or as small as allowing an moisture to get on the 'cold joint' ends it's ruined.
Sparky Joe is offline  
Sponsored Links
Advertisement
 
Old 03-25-2008, 04:58 PM   #4
DGR,IABD
 
mdshunk's Avatar
 
Trade: Electrical; Commercial and Residential Service
Join Date: Mar 2005
Location: Central PA
Posts: 9,683
Rewards Points: 2,002

Re: Lead Shielded Cable.


There's quite a bit of lead jacketed cable in my area. Forerunner to UF cable. I normally find it run to detached garages, post lights, fountains, and other places where we'd typically run UF cable today. It sure lasted a lot longer than UF. I use a UF splice kit when I have to fit the stuff. Works okay, since the repair will last as long as the rest of the cable considering the rest of the cable is probably on its last leg.
mdshunk is offline  
Old 03-25-2008, 05:28 PM   #5
Old School Marine
 
randomkiller's Avatar
 
Trade: Union Journeyman Electrician
Join Date: Sep 2007
Location: Ocean NJ
Posts: 374
Rewards Points: 250

Re: Lead Shielded Cable.


There is plenty of it under the sidewalks of Manhatten. But then again anything in the history of electric can be found in the city someplace.
__________________
"If we ever forget that we're One Nation Under God, then we will be a nation gone under." Ronald Reagan
randomkiller is offline  
Old 03-25-2008, 10:27 PM   #6
Pro
 
goose134's Avatar
 
Trade: Union Electrician
Join Date: Oct 2007
Location: Chicago
Posts: 135
Rewards Points: 75

Re: Lead Shielded Cable.


Like Random, plenty of it in Chicago. Only time I've seen it is utility transformer vaults. Although I am working at a building (c.1913) that had a lead sheathed phone cable (about 100 pair). That, I'd never seen before. They couldn't pull it out to scrap it so they cut it flush with the floor. It was in a 2" GRC.
goose134 is offline  
Old 03-31-2008, 11:14 AM   #7
Registered User
 
cosmo's Avatar
 
Trade: Electrical
Join Date: Feb 2007
Posts: 2
Rewards Points: 10

Re: Lead Shielded Cable.


We've got plenty of it at the Federal Facility I work at. In fact we purchased a 500' of 8kv 500kcmil 3 conductor PILC, 500' of 22kv 350kcmil 3 conductor gas filled PILC, and 800' of 8kv 350 kcmil 3 conductor PILC last year. Splicing lead cable is somewhat of an art form.
cosmo is offline  
Old 03-31-2008, 11:23 AM   #8
listen twice talk once!
 
Bkessler's Avatar
 
Trade: electrician
Join Date: Oct 2005
Location: Orange county California
Posts: 668
Rewards Points: 500

Re: Lead Shielded Cable.


The recent death of a la firemen that you can read about in one of these posts involved lead lined medium voltage cable.

Advertisement

Bkessler is offline  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
What Internet lead services should do to corner the market Mike Finley Business 46 12-31-2014 06:46 PM
Troubleshooting ethernet cable gravtyklz Low Voltage 17 02-07-2008 04:39 PM
Cable Calc. sparkengineer21 Electrical 2 02-06-2007 07:01 PM
encapsulating lead paint lornmastro Painting & Finish Work 17 10-03-2006 08:50 PM

Join Now... It's Fast and FREE!

I am a professional contractor
I am a DIY Homeowner
Drywall Talk is for
PROFESSIONAL CONTRACTORS ONLY!

At DrywallTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?