Window And Door Header Question - Page 2 - Framing - Contractor Talk

Window And Door Header Question

 
Thread Tools Search this Thread Display Modes
Old 09-09-2010, 05:54 PM   #21
David Festa
 
festerized's Avatar
 
Trade: Framing Contractor
Join Date: May 2007
Location: Ocean County NJ
Posts: 2,561
Rewards Points: 2,030

Re: Window And Door Header Question


Not really. My way gives options:
#1 as others have stated it not necessary to fill the void on 9 ˝” unless the header is longer than 6’
#2 If it’s in the budget and the ho wants to increase the r value then we can
festerized is offline  

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

   

Advertisement

 

Old 09-09-2010, 06:07 PM   #22
KemoSabe
 
loneframer's Avatar
 
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 14,233
Rewards Points: 12,218

Re: Window And Door Header Question


Quote:
Originally Posted by festerized View Post
We always install the void to the inside, then the insulator could install 3/8 foam or sheet rocker can install a piece of lath across the middle.
How do you follow the nailing schedule if there’s nothing to nail too?
Nailing schedule? I've never had an issue with 4-6 inch spacing at the perimeter and 8-10 inches in the field. In fact, I'd be comfortable to say that I used 15-20% more nails in sheathing than my competition, when I was framing.

I did have an issue with the inspector on an exterior inspection once. He said I needed to backnail the sheathing better, because he didn't see any streaking on the sheathing. I told him that galvanized nails don't streak. Then I showed him where galv. nails were speced on the plan. Seems he didn't realize galvies were speced on all the plans and I was the only one in town conforming.
__________________
__________________________________




"Walking the fine line between production and perfection"




__________________________________
loneframer is offline  
Old 09-09-2010, 06:11 PM   #23
KemoSabe
 
loneframer's Avatar
 
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 14,233
Rewards Points: 12,218

Re: Window And Door Header Question


Quote:
Originally Posted by festerized View Post
Not really. My way gives options:
#1 as others have stated it not necessary to fill the void on 9 ˝” unless the header is longer than 6’
#2 If it’s in the budget and the ho wants to increase the r value then we can
We always use LVLs on headers 6' or over.

As for r value, that 3/8 space is negligable. Opting for 6" walls is the best way to increase R.
__________________
__________________________________




"Walking the fine line between production and perfection"




__________________________________
loneframer is offline  
Sponsored Links
Advertisement
 
Old 09-09-2010, 06:14 PM   #24
Ruane Woodworks,LLC
 
pruane's Avatar
 
Trade: Finish and Custom Trim
Join Date: Jul 2006
Location: North Jersey
Posts: 121
Rewards Points: 79

Re: Window And Door Header Question


While we are at it, above door/ window or under top plate.
pruane is offline  
Old 09-09-2010, 06:19 PM   #25
David Festa
 
festerized's Avatar
 
Trade: Framing Contractor
Join Date: May 2007
Location: Ocean County NJ
Posts: 2,561
Rewards Points: 2,030

Re: Window And Door Header Question


I have been pushing power lam or micro lamb headers. How often do you see a power lamb headers sag like a 2x10 header would.
I understand that half the sag is coming from short liners or lack of point loads under the king stud/ liners.
Plus architects love Simpson’s plate uplift strap. (CS20) So when using these straps you no choice to but to use a solid header
festerized is offline  
Old 09-09-2010, 06:21 PM   #26
KemoSabe
 
loneframer's Avatar
 
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 14,233
Rewards Points: 12,218

Re: Window And Door Header Question


Quote:
Originally Posted by pruane View Post
While we are at it, above door/ window or under top plate.
I prefer directly above opening, then pinned to double plate. Especially with heavy French doors. Just seems more ridgid to me.
__________________
__________________________________




"Walking the fine line between production and perfection"




__________________________________
loneframer is offline  
Old 09-09-2010, 06:23 PM   #27
David Festa
 
festerized's Avatar
 
Trade: Framing Contractor
Join Date: May 2007
Location: Ocean County NJ
Posts: 2,561
Rewards Points: 2,030

Re: Window And Door Header Question


Quote:
Originally Posted by loneframer View Post
We always use LVLs on headers 6' or over.

As for r value, that 3/8 space is negligable. Opting for 6" walls is the best way to increase R.
Great 2x6 10’ walls, love it
My back hurts just typing it
festerized is offline  
Old 09-09-2010, 06:25 PM   #28
KemoSabe
 
loneframer's Avatar
 
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 14,233
Rewards Points: 12,218

Re: Window And Door Header Question


Quote:
Originally Posted by festerized View Post
I have been pushing power lam or micro lamb headers. How often do you see a power lamb headers sag like a 2x10 header would.
I understand that half the sag is coming from short liners or lack of point loads under the king stud/ liners.
Plus architects love Simpson’s plate uplift strap. (CS20) So when using these straps you no choice to but to use a solid header
Back in the day, we used full width plywood flitches on 6' or longer headers. Centered 8' rip on openings over 8', then fill in the ends. It seemed to take out some of the deflection, but we still never shimmed the center of the doors head jamb down tight.
__________________
__________________________________




"Walking the fine line between production and perfection"




__________________________________
loneframer is offline  
Old 09-09-2010, 06:33 PM   #29
KemoSabe
 
loneframer's Avatar
 
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 14,233
Rewards Points: 12,218

Re: Window And Door Header Question


Quote:
Originally Posted by festerized View Post
Great 2x6 10’ walls, love it
My back hurts just typing it
10' walls are few and far between where I've done most of my work. At times, we've had to cut 4" off of both floors to get a 3.5/12 on the roof.

Designs and restrictions have changed over the years, but still, 9' walls were about it IME.

On the other hand, 10' first floor, 9' second floor, 9' tower and 50+ foot TJI rafters with 3/4 Advantech on entire exterior....my back still hurts.
Attached Thumbnails
Window and Door Header question-294.jpg   Window and Door Header question-297.jpg  
__________________
__________________________________




"Walking the fine line between production and perfection"




__________________________________
loneframer is offline  
Old 09-09-2010, 06:36 PM   #30
David Festa
 
festerized's Avatar
 
Trade: Framing Contractor
Join Date: May 2007
Location: Ocean County NJ
Posts: 2,561
Rewards Points: 2,030

Re: Window And Door Header Question


I feel your pain
Wish PC didn’t crash a few years ago. Got some crazy framings pics I could have posted
festerized is offline  
Old 09-09-2010, 06:40 PM   #31
KemoSabe
 
loneframer's Avatar
 
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 14,233
Rewards Points: 12,218

Re: Window And Door Header Question


Quote:
Originally Posted by festerized View Post
I feel your pain
Wish PC didn’t crash a few years ago. Got some crazy framings pics I could have posted
That sucks. I don't have many framing pics of the houses I've framed. Went back and got finished pics, at least I have them.

Honestly, I didn't realize how unique most of the jobs were until several years later, when the work dried up. Guess I was just working too much to realize it.
__________________
__________________________________




"Walking the fine line between production and perfection"




__________________________________
loneframer is offline  
Old 09-09-2010, 06:44 PM   #32
David Festa
 
festerized's Avatar
 
Trade: Framing Contractor
Join Date: May 2007
Location: Ocean County NJ
Posts: 2,561
Rewards Points: 2,030

Re: Window And Door Header Question


I knew from day 1 that pictures speak louder than words. Anyone can talk the talk but having pics to back it up is the bomb
Attached Thumbnails
Window and Door Header question-arch-garage9.jpg  
festerized is offline  
Old 09-09-2010, 06:47 PM   #33
Geometrist

 
Warren's Avatar
 
Trade: framing/remodeling
Join Date: Feb 2005
Location: NE Ohio
Posts: 10,131
Rewards Points: 18

Re: Window And Door Header Question


I rarely ever took pics my first 20 years in the trades. After finding this site, I knew I had to just for bragging rights.
__________________
I'd love to replace all the dumbness in this room but the budget is tight and the stupidity is plentiful!

Easy Gibson
Warren is online now  
Old 09-09-2010, 06:48 PM   #34
KemoSabe
 
loneframer's Avatar
 
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 14,233
Rewards Points: 12,218

Re: Window And Door Header Question


A couple of my few.
Attached Thumbnails
Window and Door Header question-001-12-.jpg   Window and Door Header question-014-3-.jpg   Window and Door Header question-020.jpg  
__________________
__________________________________




"Walking the fine line between production and perfection"




__________________________________
loneframer is offline  
Old 09-09-2010, 06:59 PM   #35
David Festa
 
festerized's Avatar
 
Trade: Framing Contractor
Join Date: May 2007
Location: Ocean County NJ
Posts: 2,561
Rewards Points: 2,030

Re: Window And Door Header Question


Wish I had more pics of these condos I built.
The LBI condo was a reno,(not posted) we built the floor system under the existing roof. When were ready we cut out the trusses, finished the decking and framed the walls. They were awesome pics
Attached Thumbnails
Window and Door Header question-picture-224.jpg   Window and Door Header question-picture-226.jpg   Window and Door Header question-my-web-page-pics-033.jpg  
festerized is offline  
Old 09-09-2010, 07:01 PM   #36
Pro
 
knucklehead's Avatar
 
Trade: Extraordinary Carpenter
Join Date: Mar 2009
Location: Kansas City
Posts: 3,485
Rewards Points: 2,728

Re: Window And Door Header Question


I almost always nail mine tight together and leave the gap to the inside.No matter the width of the wall.
knucklehead is offline  
Old 09-09-2010, 07:03 PM   #37
Jeff
 
jkfox624's Avatar
 
Trade: master turd burglar
Join Date: Jun 2009
Location: Bradford PA
Posts: 1,485
Rewards Points: 502

Re: Window And Door Header Question


So im taking it you guys dont have to build 2x6 walls? Only in very rare chances can we build with 2x4 and thats like pulling teeth to get it pushed through.
jkfox624 is offline  
Old 09-09-2010, 07:04 PM   #38
KemoSabe
 
loneframer's Avatar
 
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 14,233
Rewards Points: 12,218

Re: Window And Door Header Question


Quote:
Originally Posted by knucklehead View Post
I almost always nail mine tight together and leave the gap to the inside.No matter the width of the wall.
Most areas I work expect boxed headers on 2x6 walls. I was told this is to balance the weight on the jacks and evenly distribute the load. We insulate inside the box before capping the bottom.
__________________
__________________________________




"Walking the fine line between production and perfection"




__________________________________
loneframer is offline  
The Following User Says Thank You to loneframer For This Useful Post:
jkfox624 (09-09-2010)
Old 09-09-2010, 07:15 PM   #39
Pro
 
katoman's Avatar
 
Trade: carpenter
Join Date: Apr 2009
Location: Kirkfield,Ontario, Canada
Posts: 6,102
Rewards Points: 2,000

Re: Window And Door Header Question


Putting 1/2" ply between the headers is from the days we framed walls with 2x4s, so they would match the wall thickness.

Now with 2x6 walls, we don't put ply between the lumber. And they go to the outside of the wall so you can insulate.

Headers go directly under the top plate. Jacks run up to the header. No break for the window opening.

This is code here.
katoman is offline  
Old 09-09-2010, 07:18 PM   #40
David Festa
 
festerized's Avatar
 
Trade: Framing Contractor
Join Date: May 2007
Location: Ocean County NJ
Posts: 2,561
Rewards Points: 2,030

Re: Window And Door Header Question


Quote:
Originally Posted by katoman View Post
Putting 1/2" ply between the headers is from the days we framed walls with 2x4s, so they would match the wall thickness.

Now with 2x6 walls, we don't put ply between the lumber. And they go to the outside of the wall so you can insulate.

Headers go directly under the top plate. Jacks run up to the header. No break for the window opening.

This is code here.
What about if you have a 9’ or 10’ wall? Do install header tight to pl8 or run cripples?

Advertisement

festerized is offline  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off