Forum: Electrical 12-09-2017, 06:23 PM
Replies: 4
Views: 860
Posted By wml52
Thanks for your input it very much appreciated.

Thanks for your input it very much appreciated.
Forum: Electrical 12-09-2017, 05:09 PM
Replies: 4
Views: 860
Posted By wml52
Option 2 would be to mount the meters in a 3 gang...

Option 2 would be to mount the meters in a 3 gang box mounted next to the breaker panrl. Would that be an option?
Forum: Electrical 12-09-2017, 03:03 PM
Replies: 4
Views: 860
Posted By wml52
Voltage Meter mounting location

I have a portable generator that I use for emergency backup wired into my breaker panel.

I have two meters that I would like to install into my breaker panel cover that will monitor voltage, Hz...
Forum: Electrical 12-22-2015, 10:17 PM
Replies: 12
Views: 1,837
Posted By wml52
It's a 6500 watt Honda that's about 5 years old,...

It's a 6500 watt Honda that's about 5 years old, but it's not the inverter. Just the standard brushed alternator with AVR.
Forum: Electrical 12-22-2015, 05:04 PM
Replies: 12
Views: 1,837
Posted By wml52
It took about 2-3 seconds for the voltage to...

It took about 2-3 seconds for the voltage to recover after initial start-up of both pump and furnace. Since it's capacitor regulated and doesn't have an AVR I'd agree with GettingBy that it's the...
Forum: Electrical 12-20-2015, 09:15 PM
Replies: 12
Views: 1,837
Posted By wml52
Worse case scenario for me would be to the well...

Worse case scenario for me would be to the well pump and furnace starting together so that is what I tried. The generator was able to start both with the voltage drooping to about 108 volts upon...
Forum: Electrical 12-20-2015, 05:52 PM
Replies: 12
Views: 1,837
Posted By wml52
Unfortunately the only HVAC compressor I have is...

Unfortunately the only HVAC compressor I have is on a 2 ton central air unit and I donít think that gen-set has enough in it to start that unit.
Forum: Electrical 12-11-2015, 04:14 PM
Replies: 12
Views: 1,837
Posted By wml52
Generator output voltage

I recently did some work on my Generac 5000 watt portable generator and readjusted the no-load RPM to 3740 RPM and applied various loads, here are the results: FYI this is a brushless self excited...
Forum: Electrical 11-22-2015, 10:34 PM
Replies: 3
Views: 1,119
Posted By wml52
Need a solution...

I am posting here with the hope that someone can help with a problem I came across. I will try to be as brief as possible.

I recently installed a 30-amp interlock breaker in my breaker panel for...
Showing results 1 to 9 of 9

 
Forum Jump

Join Now... It's Fast and FREE!

I am a professional contractor
I am a DIY Homeowner
Drywall Talk is for
PROFESSIONAL CONTRACTORS ONLY!

At DrywallTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?