Sewer Tie Violation
Thought you plumbers might enjoy this sewer tie violation I saw this afternoon. It was at a motel. The sewer line runs along the back of the motel (motel is on a slab), and each room dumps out into the sewer individually. This tie must have been in the process of being repaired. They took a tee, and sawed it in half, and pasted it on the side of the lateral with white caulk of some sort. The sharpie marker line on the side of the tee and the sawzall marks were very apparent. They used some sort of coupler, which was way too big for the branch, which entered at an odd angle. They filled the extra space between the coupling and the branch with more of the same white caulk. These pics are from a cell phone, but you'll get the idea. Criminal....
![]()
|
|
|
|
|
|
#2 |
|
Vagitarian
|
Re: Sewer Tie Violation
You have got to be kidding me. Nobody in their right mind could actually do that.
__________________
Life is hard. It is harder when you are stupid Uncle Sam wants YOU....to speak ENGLISH |
|
|
|
|
|
#3 |
|
I'm a Mac
Trade: ICF Construction
Join Date: Apr 2007
Location: Hog Town
Posts: 3,259
|
Re: Sewer Tie Violation
Is it just me or is that weeping tile pipe on the right side? If that's the case and it is the sewer liquid waste will disperse just fine when the clog starts
__________________
Chris Last edited by Chris Johnson; 06-14-2007 at 07:55 PM. Reason: spelling |
|
|
|
|
|
#4 | |
|
DGR,IABD
Trade: Electrical; Commercial and Residential Service
Join Date: Mar 2005
Location: Central PA
Posts: 9,680
|
Re: Sewer Tie ViolationQuote:
![]() I think you're seeing a Fernco fitting. |
|
|
|
|
|
|
#5 |
|
Pro
Trade: Plumber
Join Date: May 2007
Posts: 1,165
|
Re: Sewer Tie Violation
He got it all wrong...forgot the duct tape
|
|
|
|
|
|
#6 |
|
Insert title
Trade: Doors-Windows-Decks
Join Date: Apr 2006
Location: MA&RI
Posts: 4,677
|
Re: Sewer Tie ViolationLatex caulking holds up just as well Actually the compressed soil around the pipe works just as well.
__________________
To get the best replacement windows, or sun rooms contact the replacement windows experts at FHI Vinyl Window Company. |
|
|
|
|
|
#7 |
|
Pro
Trade: Plumber
Join Date: May 2007
Posts: 1,165
|
Re: Sewer Tie Violation
Then there are the suspect quickrete bags...good idea for back-fill...and as an aid to the latex caulking.
Makes for a nice touch with what looks like either a T-wye or a vent T running into a perpendicular main. The fact that the sewer main it runs into laterally appears to be 3 inch (for a motel with...er...how many closets tied in?) Some enterprising fella might open a roto-rooter franchise nearby... |
|
|
|
|
|
#8 |
|
Member
Trade: Remodeling
Join Date: Oct 2006
Location: South central Pennsylvania
Posts: 87
|
Re: Sewer Tie Violation
So MD, care to share what motel it was?
Joel |
|
|
|
|
|
#9 |
|
DGR,IABD
Trade: Electrical; Commercial and Residential Service
Join Date: Mar 2005
Location: Central PA
Posts: 9,680
|
Re: Sewer Tie Violation
I know nut-ting! I generally post violation pictures for entertainment and education, and not to get anyone in trouble.
Last edited by mdshunk; 06-16-2007 at 09:51 AM. |
|
|
|
|
|
#10 |
|
Pro
Trade: Wood working in spare time.
Join Date: Jan 2005
Location: kankakee county,Illinois
Posts: 1,539
|
Re: Sewer Tie Violation
Am i the only one who sees the pitch is wrong. Its going up to the union. Instead of down.
|
|
|
|
|
|
#11 |
|
Pro
Trade: plumbing
Join Date: Jan 2006
Posts: 533
|
Re: Sewer Tie Violation
The owner will have plenty of trouble when that room won't drain and neither will any room up the line. Hmmm ... $369 for a main line plus $199 per branch line coming from each room plus another $199 to reset and reseal every toilet I might have to pull if we find no accessible clean outs in the rooms multiplied by however many rooms are located up stream of this "repair". Of course a motel would never pay that. They'll just send "Ray" to fix it. Why was it being "repaired" in the first place? Did Ray just put back what he saw when he dug it up? Is every room connected this way?
|
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| sewer line cost | kenvest | Excavation & Site Work | 10 | 03-09-2007 09:20 AM |
| Sewer stub | Moscow | Plumbing | 2 | 02-27-2007 05:18 PM |
| Replacing residential sewer line | threequez | Plumbing | 1 | 10-17-2006 05:09 AM |
| Plugging sewer pipe that is to be retired | personalt | Plumbing | 3 | 07-07-2006 12:16 AM |
| Sewer gas | Texstar | Plumbing | 1 | 05-14-2006 10:30 PM |
| Go to Page... |