Sewer tie violation
Thought you plumbers might enjoy this sewer tie violation I saw this afternoon. It was at a motel. The sewer line runs along the back of the motel (motel is on a slab), and each room dumps out into the sewer individually. This tie must have been in the process of being repaired. They took a tee, and sawed it in half, and pasted it on the side of the lateral with white caulk of some sort. The sharpie marker line on the side of the tee and the sawzall marks were very apparent. They used some sort of coupler, which was way too big for the branch, which entered at an odd angle. They filled the extra space between the coupling and the branch with more of the same white caulk. These pics are from a cell phone, but you'll get the idea. Criminal....
|
|
|
Warning: The topics covered on this site include activities in which there exists the potential for serious injury
or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Join the #1 Contractor Forum Today - It's Totally Free!
ContractorTalk.com - Are you a Professional Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for contractors to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your trade is you'll find that ContractorTalk.com is a great community to join. Best of all it's totally free!
Join ContractorTalk.com - Click Here

|
06-14-2007, 06:42 PM
|
#2
|
|
Vagitarian
Trade:
site and utility contractor
Join Date: Jan 2006
Location: Dallas, PA
Posts: 2,326
|
You have got to be kidding me. Nobody in their right mind could actually do that.
__________________
Life is hard. It is harder when you are stupid
Uncle Sam wants YOU....to speak ENGLISH
|
|
|
06-14-2007, 06:53 PM
|
#3
|
|
Bunny by Malco - NY
Trade:
ICF Construction
Join Date: Apr 2007
Location: North of 49
Posts: 2,221
|
Is it just me or is that weeping tile pipe on the right side? If that's the case and it is the sewer liquid waste will disperse just fine when the clog starts
__________________
Chris
Last edited by Chris Johnson; 06-14-2007 at 06:55 PM.
Reason: spelling
|
|
|
06-14-2007, 06:58 PM
|
#4
|
|
DGR,IABD
Trade:
Electrical; Commercial and Residential Service
Join Date: Mar 2005
Location: Central PA
Posts: 9,665
|
Quote:
Originally Posted by rino1494
You have got to be kidding me. Nobody in their right mind could actually do that.
|
Nope.. no kidding. It was the motel's maintenance man who did it. His name is Ray, and he stays in room 109. Claims to have 4 grand in tools in his room. Wish he'd have used them. He also claimed to be an expert electrician, yet I was called.
Quote:
Originally Posted by Chris Johnson
Is it just me or is that weeping tile pipe on the right side? If that's the case and it is the sewer liquid waste will disperse just fine when the clog starts
|
I think you're seeing a Fernco fitting.
|
|
|
06-14-2007, 07:50 PM
|
#5
|
|
Pro
Trade:
Plumber
Join Date: May 2007
Posts: 1,156
|
He got it all wrong...forgot the duct tape
|
|
|
06-14-2007, 07:53 PM
|
#6
|
|
Insert title
Trade:
Doors-Windows-Decks
Join Date: Apr 2006
Location: MA&RI
Posts: 4,556
|
Quote:
Originally Posted by Grumpyplumber
He got it all wrong...forgot the duct tape
|
Latex caulking holds up just as well  Actually the compressed soil around the pipe works just as well.
|
|
|
06-14-2007, 08:00 PM
|
#7
|
|
Pro
Trade:
Plumber
Join Date: May 2007
Posts: 1,156
|
Then there are the suspect quickrete bags...good idea for back-fill...and as an aid to the latex caulking.
Makes for a nice touch with what looks like either a T-wye or a vent T running into a perpendicular main.
The fact that the sewer main it runs into laterally appears to be 3 inch (for a motel with...er...how many closets tied in?)
Some enterprising fella might open a roto-rooter franchise nearby...
|
|
|
06-16-2007, 06:55 AM
|
#8
|
|
Member
Trade:
Remodeling
Join Date: Oct 2006
Location: South central Pennsylvania
Posts: 82
|
So MD, care to share what motel it was?
Joel
|
|
|
06-16-2007, 08:49 AM
|
#9
|
|
DGR,IABD
Trade:
Electrical; Commercial and Residential Service
Join Date: Mar 2005
Location: Central PA
Posts: 9,665
|
Quote:
Originally Posted by Edsollen
So MD, care to share what motel it was?
Joel
|
I know nut-ting! I generally post violation pictures for entertainment and education, and not to get anyone in trouble.
Last edited by mdshunk; 06-16-2007 at 08:51 AM.
|
|
|
06-16-2007, 09:49 PM
|
#10
|
|
Pro
Trade:
Wood working in spare time.
Join Date: Jan 2005
Location: kankakee county,Illinois
Posts: 1,508
|
Am i the only one who sees the pitch is wrong. Its going up to the union. Instead of down.
|
|
|
07-04-2007, 10:36 AM
|
#11
|
|
Pro
Trade:
plumbing
Join Date: Jan 2006
Posts: 532
|
Quote:
Originally Posted by mdshunk
I know nut-ting! I generally post violation pictures for entertainment and education, and not to get anyone in trouble.

|
The owner will have plenty of trouble when that room won't drain and neither will any room up the line. Hmmm ... $369 for a main line plus $199 per branch line coming from each room plus another $199 to reset and reseal every toilet I might have to pull if we find no accessible clean outs in the rooms multiplied by however many rooms are located up stream of this "repair". Of course a motel would never pay that. They'll just send "Ray" to fix it. Why was it being "repaired" in the first place? Did Ray just put back what he saw when he dug it up? Is every room connected this way?
|
|
|