11-17-2009, 10:50 AM
|
#1
|
|
Pro
Trade:
General contractor
Join Date: May 2008
Location: Carbon county Wyoming
Posts: 326
|
Clean out Clean out
I have a sewer latteral to run this week for another builder/friend of mine and he wants me to put the clean out in the crawl space. I always put the clean out out side about two foot away from the foundation using a wye and a 45. I do not like placing it in the basement or crawl space because if you have a blockage and have to use the clean out you end up with a crawl space full of **^% and you have to drag your clean out snake to the crawl space. So I am just curious what most of you guys like?
|
|
|
Warning: The topics covered on this site include activities in which there exists the potential for serious injury
or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Join the #1 Contractor Forum Today - It's Totally Free!
ContractorTalk.com - Are you a Professional Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for contractors to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your trade is you'll find that ContractorTalk.com is a great community to join. Best of all it's totally free!
Join ContractorTalk.com - Click Here

|
11-18-2009, 08:46 PM
|
#2
|
|
Pro
Trade:
Excavation, land clearing, sewer/water
Join Date: Dec 2007
Posts: 191
|
Outside..... Just like you!
|
|
|
11-18-2009, 09:43 PM
|
#3
|
|
Pro
Trade:
General, Electrical, and Plumbing Contractor
Join Date: Feb 2007
Location: Portland, OR & Eatonville, WA
Posts: 858
|
Outside also, what does the code say there.
If they are concerned about how it looks, put it in a flush to grade valve box.
I use these a lot for clean-outs and for septic system lateral clean-outs.
http://www.carsonind.com/PDF/Specifi...0Grade/708.pdf
|
|
|
11-18-2009, 11:57 PM
|
#4
|
|
The Grand Wazoo
Trade:
Popcorn Vendor
Join Date: May 2007
Location: Illinois
Posts: 2,308
|
When I did service work a cleanout in a crawl usually prevented us from getting the machine into the crawl to access the CO, and we ended up digging outside to install a CO and making the CO in the crawl useless.
|
|
|
11-19-2009, 11:53 PM
|
#5
|
|
Registered User
Trade:
Licensed General Contractor
Join Date: Nov 2009
Location: California
Posts: 9
|
"...he wants me to put the clean out in the crawl space."
Why?
|
|
|
11-21-2009, 01:06 AM
|
#6
|
|
Pro
Trade:
General contractor
Join Date: May 2008
Location: Carbon county Wyoming
Posts: 326
|
I have no idea why he wants it in the crawl space! Code? This is Wyoming half the state has no enforcement and no building departments. Not having code enforcement is not all its cracked up to be. I replaced a sewer latteral two weeks ago that in the last six feet ran uphill 3"s to the main and to clean it out you had to pull a toilet. Thanks for the answers and the the link.
|
|
|
11-21-2009, 01:14 AM
|
#7
|
|
Pro
Trade:
LI,NY designer, new homes, renovation work, concre
Join Date: Mar 2008
Location: Long Island, NY
Posts: 5,087
|
They are often placed in crawlspaces around here, as much as the crawlspace might be full of sh## and hard to get to, there could be 2ft of snow and frozen ground. GMOD
__________________
|
|
|
11-22-2009, 08:50 AM
|
#8
|
|
New Guy
Trade:
Plumbing
Join Date: Dec 2008
Posts: 29
|
Quote:
Originally Posted by wyoming 1
I have a sewer latteral to run this week for another builder/friend of mine and he wants me to put the clean out in the crawl space. I always put the clean out out side about two foot away from the foundation using a wye and a 45. I do not like placing it in the basement or crawl space because if you have a blockage and have to use the clean out you end up with a crawl space full of **^% and you have to drag your clean out snake to the crawl space. So I am just curious what most of you guys like?
|
What I like is when a GC, HIRES A PROFESSIONAL PLUMBER THAT IS LICENSED PROPERLY for that kind of work. And why a wye, and 1/8 bend? A PROFESSIONAL PLUMBER would install a two way clean out. For rodding both directions.  Imagine that.
|
|
|
|
The Following User Says Thank You to ROCKSTARPLUMBER For This Useful Post:
|
|
11-24-2009, 07:30 AM
|
#9
|
|
Pro
Trade:
Electrical & Carpentry
Join Date: Dec 2008
Location: Adirondacks of NY
Posts: 474
|
Quote:
Originally Posted by genecarp
They are often placed in crawlspaces around here, as much as the crawlspace might be full of sh## and hard to get to, there could be 2ft of snow and frozen ground. GMOD
|
Thanks Gene - Same here. I think it would depend on the area you live in. With all the snow we get around here "a Plumber" would be busy trying to "find" the cleanouts................
|
|
|
11-25-2009, 10:10 PM
|
#10
|
|
New Guy
Trade:
Plumbing
Join Date: Dec 2008
Posts: 29
|
Quote:
Originally Posted by mrmike
Thanks Gene - Same here. I think it would depend on the area you live in. With all the snow we get around here "a Plumber" would be busy trying to "find" the cleanouts................
|
Well, it would suck to be up there then. Nothing like opening up a cleanout in a crawl space thats full of chit and piss.
|
|
|