Auto Shut SS Supply Lines
Do you use them?
I have replaced a few but don't use them myself. |
|
|
|
|
|
#2 |
|
The Grand Wazoo
Trade: It blowed up real good!
Join Date: May 2007
Location: Illinois
Posts: 3,090
|
Re: Auto Shut SS Supply Lines
We don't use flexible supplies at all, unless it is a temporary fixture.
__________________
A flush is better than a full house. |
|
|
|
|
|
#3 |
|
Plumber / Carpenter
|
Re: Auto Shut SS Supply Lines
Auto shut off?? never heard of that. Now the SS (Stainless Steel) yes, I have used them, not much though. Usually on commercial or other places where a water fed fixture may need to be moved in and out. Cheap plumbing contracts, Pex, High end chrome.
|
|
|
|
|
|
#4 |
|
Pro Plumber
Trade: Plumber
Join Date: Oct 2006
Posts: 2,779
|
Re: Auto Shut SS Supply Lines
So I go on this call, no water to the hot side of a lav faucet, odd I think before I get there, there is hot to all other fixtures, I get there and think it could be the faucet, I look under the sink and here are those supplies, remove the supply and install the regular ones, all fine and dandy.
So what made the auto shut off supply to prematurely shut off, I really don't know how these work, is it the flow rate passing through the faucet that determines the supply line to allow the flow or shut it off? If there worth anything, there definitely a service call generator, which is a good thing for a business, nice easy fix to solve the problem. |
|
|
|
|
|
#5 |
|
Licensed Electrician
Trade: Licensed Electrictian
Join Date: Feb 2006
Location: Middle TN.
Posts: 249
|
Re: Auto Shut SS Supply Lines
We use SS flex lines all the time. Not auto shut-off, though.
__________________
Follower of Jesus Christ |
|
|
|
|
|
#6 |
|
Pro Plumber
Trade: Plumber
Join Date: Oct 2006
Posts: 2,779
|
Re: Auto Shut SS Supply Lines |
|
|
|
|
|
#7 |
|
Pro
Trade: plumbing
Join Date: Jan 2006
Posts: 533
|
Re: Auto Shut SS Supply Lines
I had started using these a while back because it sounds like a great product but I started having the exact same problem. After a couple of call backs I realized they were a liability rather than a profit producer so I quit using them. I still use ss braid on washing machine lines only as an upsell but not with the auto shut off.
|
|
|
|
|
|
#8 |
|
Licensed Electrician
Trade: Licensed Electrictian
Join Date: Feb 2006
Location: Middle TN.
Posts: 249
|
Re: Auto Shut SS Supply Lines
Not auto shut-off. I realized I omited that part, sorry.
__________________
Follower of Jesus Christ |
|
|
|
|
|
#9 |
|
Pro
Trade: plumbing
Join Date: Jan 2006
Posts: 533
|
Re: Auto Shut SS Supply Lines
??? Do you mean like a chrome faucet supply only for a washing machine?
|
|
|
|
|
|
#10 |
|
Licensed Electrician
Trade: Licensed Electrictian
Join Date: Feb 2006
Location: Middle TN.
Posts: 249
|
Re: Auto Shut SS Supply Lines
We use them for about everything, refrig/ice/water, lavatories, toilets, sinks, etc....the SS flex type. So far so good.
__________________
Follower of Jesus Christ |
|
|
|
|
|
#11 |
|
Pro
Trade: plumbing
Join Date: Jan 2006
Posts: 533
|
Re: Auto Shut SS Supply Lines
I got called out to a flooded house about a year ago. ss braided dishwasher supply literally blew apart. Around the circumference of the line the ss was just uniformly peeled back like a little bomb went off. It was only attached by a handful of ss threads. Never seen it before or since but it was enough to get me to sell nothing but copper supplies except for washing machine. I wish I could post a picture of the ruptured line, I have tried but the file size is too big and I don't know how to get it small enough to post.
|
|
|
|
|
|
#12 | |
|
The Grand Wazoo
Trade: It blowed up real good!
Join Date: May 2007
Location: Illinois
Posts: 3,090
|
Re: Auto Shut SS Supply LinesQuote:
__________________
A flush is better than a full house. |
|
|
|
|
|
|
#13 | |
|
Pro Plumber
Trade: Plumber
Join Date: Oct 2006
Posts: 2,779
|
Re: Auto Shut SS Supply LinesQuote:
Free image resizer, works great. http://www.vso-software.fr/products/image_resizer/ |
|
|
|
|
|
|
#14 | |
|
Pro
Trade: plumbing
Join Date: Jan 2006
Posts: 533
|
Re: Auto Shut SS Supply LinesQuote:
|
|
|
|
|
|
|
#15 |
|
Pro Plumber
Trade: Plumber
Join Date: Oct 2006
Posts: 2,779
|
Re: Auto Shut SS Supply Lines |
|
|
|
|
|
#16 |
|
Pro
Trade: Plumber
Join Date: May 2007
Posts: 1,165
|
Re: Auto Shut SS Supply Lines
First and last experience with an auto shut off...
Installed a toilet & picked one up to try it out. Homeowner standing there right as I finish off connecting the feed...open the valve and "thump"..it shuts off, leaving me there trying to figure out what the hell I did wrong. Turns out they had borderline hiigh pressure. If the pressure is too high, they trigger. Makes me wonder...if the pressure builds over-night as the water heater reheats...then the H.O. uses the toilet right after thermal expansion that morning and it does it's thing...you're going back there the next day. |
|
|
|
|
|
#17 |
|
Pro
Trade: carpenter/ handyman
Join Date: Dec 2007
Location: Conroe, TX
Posts: 1,668
|
Re: Auto Shut SS Supply Lines
The don't work properly if the water pressure is set too high. I don't even see them at Home Depot anymore.
Steve |
|
|
|
|
|
#18 |
|
Pro Plumber
Trade: Plumber
Join Date: Oct 2006
Posts: 2,779
|
Re: Auto Shut SS Supply Lines
If you send it to me I'll resize and post for you, PM me if you want.
|
|
|
|
|
|
#19 |
|
Pro
Trade: plumbing
Join Date: Jan 2006
Posts: 533
|
Re: Auto Shut SS Supply Lines
Hope this works.
|
|
|
|
|
|
#20 |
|
Pro
Trade: plumbing
Join Date: Jan 2006
Posts: 533
|
Re: Auto Shut SS Supply Lines
Woo hoo! I found another photo of the same thing with a smaller file size.
|
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Lead supply lines? | orson | Plumbing | 3 | 02-09-2008 11:42 AM |
| Sink Garbage disposal will not shut off | smcgowan@msn.co | Electrical | 4 | 06-08-2006 01:16 AM |
| Flushmount Light with MIN 90C Supply Conductors | kpikul | Electrical | 1 | 11-15-2005 06:41 PM |
| Go to Page... |