In the learning
|
AFCI Protection Porject In Class
I am currently a student at Triangle Tech Greensbug Campus. We are doing a research project and I got selected for this question. In old installations, do you need to AFCI protect a circuit? What if you use a GFCI receptacle and the AFCI breaker, will both serve their purpose and work? Does it all depend on the inspector? I know that in the 05 version of code stated bedrooms and hallways needed AFCI circuit protection in only new installations. In the 08 version all rooms other than those GFCI protected. In my current class of power distribution, we have talked about both AFCI and GFCI devices. Is it possible to have a GFCI receptacles on AFCI breakers and both do their functions? I know this would be expensive due to the price of the AFCI breakers at roughly $50 a piece and the GFCI receptacles at $14 a piece roughly. Thanks for your inputs....
|
|
|
|
|
|
#2 |
|
And I do electrical, too!
Trade: DEFENDER OF FREEDOM! ADVOCATE OF LIBERTY!
Join Date: Jan 2009
Location: Iowa
Posts: 5,397
|
Re: AFCI Protection Porject In Class
Today's AFCIs are totally compatible with GFCIs. It does not depend on the inspector.
__________________
Site : the area or exact plot of ground on which anything is, has been, or is to be located. Sight : The power or faculty of seeing; perception of objects by use of the eyes; vision. Cite : To mention in support, proof, or confirmation; refer to as an example. |
|
|
|
|
|
#3 |
|
ampman
Trade: providing pathways for electrons and protons
Join Date: Apr 2009
Location: central florida
Posts: 778
|
Re: AFCI Protection Porject In Class
if you hear the term combination type arc faults it refers to a device that will protect against series and parallel arc faults not a gfi/afci combo but i did read that such a device does exist.
__________________
an army of sheep lead by a lion will defeat an army of lions lead by a sheep |
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Security wire code?? | Jason Whipple | Low Voltage | 24 | 03-19-2009 09:02 PM |
| AFCI breaker question. | Jeff (socal) | Electrical | 24 | 12-27-2008 03:29 PM |
| Can You Recommend An Exam Preparation Class For California "B" Licesne? | DavidG19 | Contractor Licensing | 4 | 12-09-2008 06:53 PM |
| Kohler class 6 | Wallace 49 | Plumbing | 4 | 12-03-2008 11:44 AM |
| Eyebrow Framing Class | Timuhler | Carpentry | 2 | 11-14-2008 10:31 PM |
| Go to Page... |