Proper Abandonment Of Transite Wate Pipe?
Curious as to if anyone knows what is considered to be the proper abandonment procedure for Transite (Asbestos) water pipe. We have a job at a local high school to replace 600 linear feet of existing transite water main with C909 Plastic water pipe. Historically we have capped the end of the pipe and left the pipe where it lies. But we have been questioned if this is proper procedure to meet Massachusetts state law. I have asked the local water department and they said it is often left where it is. Any input on the subject would be apreciated. Thanks In Advance.
|
|
|
|
|
|
#2 |
|
Pro
Trade: entrepreneur of excavating expertise
Join Date: Mar 2006
Posts: 2,605
|
Re: Proper Abandonment Of Transite Wate Pipe?
i'm sure state laws vary, but here, they're capped, and left. only time it becomes a hazard is when the fibers in the pipe are in suspension. i personally can't see any reason to change things.
__________________
someday, i'll be as patient as Nick. |
|
|
|
|
|
#3 |
|
DGR,IABD
Trade: Electrical; Commercial and Residential Service
Join Date: Mar 2005
Location: Central PA
Posts: 9,680
|
Re: Proper Abandonment Of Transite Wate Pipe?
Bury it next to the haunches of the new pipe.
|
|
|
|
|
|
#4 |
|
Member
Trade: site work
Join Date: Dec 2007
Posts: 96
|
Re: Proper Abandonment Of Transite Wate Pipe?
you can smash it and leave in in place if you want too we have done that a few times
|
|
|
|
|
|
#5 |
|
Handle It!
Trade: Everything The Union Guys Do Not Want To Do
Join Date: Feb 2008
Location: Brooklyn, NY ~ Haverford, PA
Posts: 9,384
|
Re: Proper Abandonment Of Transite Wate Pipe?
And create Airborne Asbestos Particles??? Hmmmmmmmm........
__________________
Something to One may be Nothing to another! Ultimate Wisdom--------- http://www.youtube.com/watch?v=OW-cnizLDEE |
|
|
|
|
|
#6 |
|
Pro
Trade: General, Electrical, and Plumbing Contractor
Join Date: Feb 2007
Location: Portland, OR & Eatonville, WA
Posts: 1,265
|
Re: Proper Abandonment Of Transite Wate Pipe?
Her in Oregon and Washington we can only leave it in the ground for a couple of reasons, otherwise it must be removed. If done by the rules you can remove it yourself and dispose of it at a landfill the takes in asbestos waste as long as all transport paperwork is done.
But you need to check what your states laws and rules are on this, here in the western states the laws and rules are all the same and use Federal EPA guide lines. Link to a PDF file from Oregon DEQ, HOW TO REMOVE NONFRIABLE ASBESTOS (AC) WATER PIPE A Guide for Meeting DEQ Ruleshttp://www.deq.state.or.us/aq/asbestos/docs/ASBPIPE.pdf |
|
|
|
|
|
#7 |
|
Pro
Trade: General, Electrical, and Plumbing Contractor
Join Date: Feb 2007
Location: Portland, OR & Eatonville, WA
Posts: 1,265
|
Re: Proper Abandonment Of Transite Wate Pipe? |
|
|
|
|
|
#8 |
|
Member
Trade: site work
Join Date: Dec 2007
Posts: 96
|
Re: Proper Abandonment Of Transite Wate Pipe?
See ive been told in towns that if you break it and leave it in place your fine. most of the time we jus find old drain lines and stuff no one knows about so you break them anyway
|
|
|
|
|
|
#9 |
|
Stud
Trade: Excavation
Join Date: Apr 2009
Location: Mass
Posts: 419
|
Re: Proper Abandonment Of Transite Wate Pipe?
In Western Mass. I know of a company that got fined for not disposing of transite pipe properly. I heard that it was very clear in the job specs but they ignored the specs. I would investigate a little further because DEP & EPA isn't going to care what the local water dept told you. It's always a gamble because you never know if someone just passing by turns you in and you get a big fine. I ask some local guys that work on public jobs how they dispose of it.
|
|
|
|
|
|
#10 |
|
Pro
Trade: General, Electrical, and Plumbing Contractor
Join Date: Feb 2007
Location: Portland, OR & Eatonville, WA
Posts: 1,265
|
Re: Proper Abandonment Of Transite Wate Pipe?
Just looked at the Massachusetts asbestos regulations.
You are the same as us here on the west coast, they follow Federal EPA rules and guidelines. And it seems all the states follow Federal EPA rules. Massachusetts DEP, asbestos page http://www.mass.gov/dep/air/asbguid.htm |
|
|
|
|
|
#11 |
|
Pro
Trade: General, Electrical, and Plumbing Contractor
Join Date: Feb 2007
Location: Portland, OR & Eatonville, WA
Posts: 1,265
|
Re: Proper Abandonment Of Transite Wate Pipe?
And just to let you know what the fines, etc. are for violations out here.
What are penalties for non-compliance? The Agency can assess a monetary civil penalty up to $15,127.00 per day per violation. If an economic benefit is realized by non-compliance, the penalty can reflect this estimated cost which is often non negotiable. Criminal sanctions may occur for a knowing or willful violation. |
|
|
|
|
|
#12 |
|
Registered User
Trade: Utility Contractor
Join Date: Jan 2009
Location: Grafton, MA
Posts: 15
|
Re: Proper Abandonment Of Transite Wate Pipe?
Thanks for the input, today the water department and a rep. from the Mass Water Works Association, and they both told us to leave it in place and cap the two ends. They tell us this is what they are doing on the other projects they are doing at this time when the renew their own water mains. Once again thaks for all the replies.
|
|
|
|
|
|
#13 | |
|
Pro
Trade: Excavation
Join Date: Feb 2009
Location: Saginaw Michigan
Posts: 272
|
Re: Proper Abandonment Of Transite Wate Pipe?Quote:
|
|
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Designing a dust-collection system for my shop: any problem using 6" pipe? | Panzer5 | Tools & Equipment | 24 | 05-19-2009 10:34 AM |
| condesating steam pipe | Platinum8 | Plumbing | 6 | 04-27-2009 08:29 PM |
| Pre-calculate DWV pipe lengths between fittings? | bob_cntrctr | Plumbing | 1 | 01-20-2009 01:08 PM |
| Very clean galvanized pipe. | silvertree | Plumbing | 14 | 09-14-2008 03:47 PM |
| Proper pipe bracing and support?? | Shoreline58 | Plumbing | 2 | 07-01-2008 09:01 AM |
| Go to Page... |