Old 09-03-2005, 03:05 PM   #1
Registered User
Trade: Low voltage electrical
 
Join Date: Sep 2005
Posts: 4
Trane or American Standard?

I just received a quote from a highly recommended AC contractor to replace an 18 yr old 4 ton split system with a new American Standard system. He is recommending the variable speed air handler and condensing unit with the dual speed compressor and EER of 16.35 and R410a instead of R22. When I asked him about Trane he said I could pay more for the name but the name was about all I was getting, and that the EER was a little higher but not that much. (17.25) He als feels that there may be shortages of R22 in the future so R410a is tha way to go. Comments? Advice?
Ed
Palm Beach Gardens, FL

EdBickford is offline   Reply With Quote
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Join Contractor Talk

Join the #1 Contractor Forum Today - It's Totally Free!

ContractorTalk.com - Are you a Professional Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for contractors to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your trade is you'll find that ContractorTalk.com is a great community to join. Best of all it's totally free!

Join ContractorTalk.com - Click Here JOIN FOR FREE

Old 09-03-2005, 05:28 PM   #2
DGR,IABD
 
mdshunk's Avatar
Trade: Electrical; Commercial and Residential Service
 
Join Date: Mar 2005
Location: Central PA
Posts: 9,665
Your contractor was right. Trane and American Standard are the same unit (same company) much like Carrier and Bryant are the same, and Goodman and Janitrol are the same, York and Luxaire are the same, etc., etc.
mdshunk is offline   Reply With Quote
Old 09-04-2005, 07:25 AM   #3
The Doctor is In!
 
HVAC Doc's Avatar
Trade: HVAC owner
 
Join Date: Apr 2004
Location: Kansas
Posts: 227
Ed, your contractor and MD are correct. Just check this out http://www.americanstandard.com/Overview_HC.asp to see that no one is pulling your leg.
HVAC Doc is offline   Reply With Quote
Old 09-07-2005, 05:40 PM   #4
Registered User
Trade: Low voltage electrical
 
Join Date: Sep 2005
Posts: 4
Quote:
Originally Posted by HVAC Doc
Ed, your contractor and MD are correct. Just check this out http://www.americanstandard.com/Overview_HC.asp to see that no one is pulling your leg.

Thanks for the response. I recevied a second quote today from a Trane dealer and the rebate Trane is currently offering makes Trane less expensive so i think i will go with that. I got a different opinion though on using R410a, The Trane dealer told me the higher operating pressures of 410a are causing a significant number of leaks. Anyone experiencing that?

Ed
EdBickford is offline   Reply With Quote
Old 09-07-2005, 07:16 PM   #5
The Doctor is In!
 
HVAC Doc's Avatar
Trade: HVAC owner
 
Join Date: Apr 2004
Location: Kansas
Posts: 227
LOL sounds like he doesn't want to deal with 410a. Brazing is Brazing be it R-22 or R-410a. The bursting strength of a good brazed joint still far exceeds the operating pressures of 410a. Here is a site that also dispells many other "myths" of 410a http://www.410a.com/myths/02.html . We sell Carrier, Lennox, and Amana and I have sold Carrier's 410a systems since 1998. Other than a lightning strike a few years ago and some power surges from our major ice storm that hit in January, the 410a units are as or more reliable.
HVAC Doc is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
New OSHA standard OsNap Health & Safety 8 01-08-2010 09:19 PM
Trane versus American Standard Central Air Unregistered HVAC 4 05-08-2008 05:51 PM
American Standard Whirlpool pump bad? nobody Plumbing 5 11-07-2006 10:28 PM
American Standard Champion toilet Steampiper Plumbing 8 07-21-2006 03:57 PM
American Standard or Carrier? Bigvree HVAC 4 02-03-2006 08:10 PM