Heatway Radiant

Has anybody here used any of the "old" Heatway tubing for radiant systems?
I put this stuff in my house when I built it back in '94. There was just a large class action settlement with Goodyear over hose failure. I was wondering if anybody has seen any of these failures?

TimNJ is offline   Reply With Quote
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Join Contractor Talk

Join the #1 Contractor Forum Today - It's Totally Free!

ContractorTalk.com - Are you a Professional Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for contractors to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your trade is you'll find that ContractorTalk.com is a great community to join. Best of all it's totally free!

Join ContractorTalk.com - Click Here JOIN FOR FREE

Old 09-09-2005, 07:15 PM   #2
Pro
Trade: plumbing and heating
 
Join Date: May 2005
Location: MA
Posts: 295
I've used it in the past for fishing a line from a existing home (zone) to an addition, 3' to 4' sections at the most. I know guys who have used miles of it, but I havent heard any thing bad about it!
plumguy is offline   Reply With Quote
Old 09-10-2005, 05:00 AM   #3
Bjd
Pro
Trade:
 
Join Date: Dec 2003
Location: MA
Posts: 438
Are you talking about the red heatwy or the black onex type?

BJD
Bjd is offline   Reply With Quote
Old 09-10-2005, 06:21 PM   #4
Pro
Trade: Remodeler
 
Join Date: Sep 2005
Posts: 930
Yeah, red or mine was more orange color though.
TimNJ is offline   Reply With Quote
Old 09-10-2005, 09:19 PM   #5
The Doctor is In!
 
HVAC Doc's Avatar
Trade: HVAC owner
 
Join Date: Apr 2004
Location: Kansas
Posts: 227
Here is an old press release article I found when we had installed a few radiant systems in the early 90's. It was designed to help us (the contractors) deal with questions about Heatways products:

Heatway's Entran II, which was manufactured by Goodyear from 1989 to 1994, has had numerous failures in the field. The hose made from nitrile rubber, in some cases, turned deep brownish red and became brittle and easily broken within two years of operation. Heatway indicates that currently only a small portion (far less than 10%) of the Entran II installed has experienced this problem.

Heatway also states that any contractor who has been on a job site and witnessed a single piece of Entran II hard at the manifold, soft five feet in, and then hard again, knows that the pipe is the issue, not the quality of water, system operation or installation techniques. Heatway readily acknowledges that the tube itself is defective. We are also quick to point out that only the Entran II is in question, as it is our only product made from nitrile rubber. The original Entran I, Entran III, Entran IIId, and the current Entran Onix are all made from a completely different formulation of high temperature EPDMs that have a proven record. These products are manufactured by Dayton Rubber, not Goodyear.

Heatway originally switched in 1989 to Goodyear from Dayton as a manufacturer of their hose because Goodyear promised an improved product over the Entran I. Heatway even agreed to pay more for the product based on the promised improvements which had to do primarily with the oxygen diffusion issue. Goodyear produced the nitrile rubber hose from a closely guarded formulation which was not even revealed to Heatway personnel.

Heatway is currently in legal negotiations with Goodyear to sort out who is responsible. They feel strongly that Goodyear should stand behind its product and assist them in servicing those customers who have encountered the problem. Goodyear has taken the stance that, "customers should look to Heatway Systems to honor its warranty responsibilities ... and not Goodyear."

Even though the defective tube has shown up in relatively few installations, all Entran II hose is suspect. Only time will tell if all or only a portion of the product will fail. In the meantime, Heatway is attempting to deal with the problem head on. They have established a special web page called Goodyear Made Entran 2 to answer questions, provide information and collect data on all Entran projects.

Heatway has built a reputation on quality customer service and a readiness to stand behind its product. The scope of the problem could be enormous if all Entran II proves to be defective and could stretch Heatway well beyond its capacity to cope. They believe that Goodyear will step up to the plate and assist in the job of making things right with their customers.

Bad news spreads fast and tubing failure is our industry's worst nightmare. This is not just a Heatway problem ... it affects us all. A knee-jerk reaction could severely dampen the positive growth we have seen in recent years. It is imperative that the industry cope with this situation in a constructive manner. The public will tend to lump all radiant floor heating systems into the same category with Entran II. It is our job to make sure that customers understand the difference.

Here is what you should tell customers:

1. The defective hose, Entran II, is the only radiant floor tubing made from nitrile rubber.
2. The vast majority of radiant floor tubing is manufactured from plastic or rubber formulations that have been installed and tested for well over thirty years.
3. Heatway is a responsible company and is making every effort to provide a solution for the affected customers.
4. Those wanting more information on Entran II can visit the special Internet site Heatway has set up at http://www.gme2.com.

Keep in mind that Heatway did not intentionally go to market with defective merchandise. We felt that we were investing their future in a superior product. This is a time when the best and wisest thing our industry can do is to support our injured comrade and help minimize the damage done.
HVAC Doc is offline   Reply With Quote
Old 09-11-2005, 02:14 PM   #6
Pro
Trade: Remodeler
 
Join Date: Sep 2005
Posts: 930
Well so much for that. I am about 90% sure Heatway filed for bankruptcy and was bought out by Watts. The case went to court against Goodyear and they lost a $300 million class action settlement. In the early 90's when I was designing my house Heatway was one of the only companies doing radiant. I used their design which turned out to be S*@t. I ended up ripping out all my piping (not radiant tubing) on my boiler and redesigning the system myself based on a hydronic heating book called "Pumping Away". The entire system works great now. The only problem I was left with was Heatway design had my tubing in slab spaced too far apart so I have to run a higher temp in my radiant than I would prefer (135deg vs 120deg).
TimNJ is offline   Reply With Quote
Old 09-11-2005, 06:37 PM   #7
DGR,IABD
 
mdshunk's Avatar
Trade: Electrical; Commercial and Residential Service
 
Join Date: Mar 2005
Location: Central PA
Posts: 9,665
Quote:
Originally Posted by TimNJ
I ended up ripping out all my piping (not radiant tubing) on my boiler and redesigning the system myself based on a hydronic heating book called "Pumping Away".
Dan Holohan is the absolute best author with respect to hydronic!! I have everything he ever wrote.
mdshunk is offline   Reply With Quote
Old 09-11-2005, 06:53 PM   #8
Pro
Trade: plumbing and heating
 
Join Date: May 2005
Location: MA
Posts: 295
Quote:
Originally Posted by mdshunk
Dan Holohan is the absolute best author with respect to hydronic!! I have everything he ever wrote.
:Thumbs: :Thumbs: :Thumbs:
plumguy is offline   Reply With Quote
Old 01-16-2006, 08:24 PM   #9
Registered User
Trade: Mechanical
 
Join Date: Jan 2006
Posts: 2
Was it the glycol solution that rotted the piping away or what? I want to say Dow Thermal has some that has inhibitors in it that keeps their solutions from corroding the tubes......which sucks on a closed system because they are so much more expensive.
Chad is offline   Reply With Quote
Old 01-19-2006, 09:38 PM   #10
Pro
Trade: Remodeler
 
Join Date: Sep 2005
Posts: 930
This was water and glycol that caused the problems. The Heatway tube (Entran) was basically like mini radiator hose. I had somebody come out in Dec. to inspect my tubing to verify that I had Entran. Waiting for a response now. Supposedly 60 days wait, so they have about two more weeks.
TimNJ is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
radiant heat system maderuyck HVAC 4 08-17-2008 07:14 PM
Radiant Floors using floor joists and reflective barriar Jacey Flooring 1 07-06-2007 12:04 PM
Demo a foundation under a radiant heat slab without disturbing the slab...? wackman Remodeling 18 04-01-2007 11:38 PM
Wood Floor and Rosin Paper over Radiant cyepsen Flooring 2 03-08-2007 09:50 PM
Misc. Radiant Heating Parts phdboss1 Contractor Swap 1 08-20-2006 08:20 PM




Top of Page | View New Posts


All times are GMT -5. The time now is 02:24 AM.


Contractor Talk™ © 2003 - 2009 The Building Network LLC