Thread Tools | Search this Thread | Display Modes |
|
|
#1 |
|
Registered User
Trade: Construction
Join Date: Jun 2005
Posts: 2
|
Carrier 48ss
First off, I am NOT a HVAC tech nor do I claim to be. I'm not even a DIYer when it comes to HVAC. I am a donut maker by trade (photographer by passion), but I AM looking for some straight answers. I know I'll prolly be kicked out of here, but I would like some help from you hard working HVAC professionals.
I have a Carrier 48 ss on top of my (donut) shop that was manufactured 3-97 and installed 7-97. In '98 it worked well. Not perfect or even great, but well. From spring of '99 until present I've had to call the same company out, sometimes several times, to get it to work again, only to last the season and that's it. Every time it's "I can't find anything wrong with it and that will be $$$ dollars." I'm on my third compressor now which was installed less than two months ago and it's already dying. I. E. the Tstats set on 72 and it won't cool below 80, and is prgressively getting worse. I guess they won't stand behind thier work or product considering they keep charging me, but is this right? Is it possible to have gotten a lemon of an a/c unit? Have any of you had this kind of bad experience with this brand/model? Was there a recall on this unit or something per chance? I've also contacted Carrier about this problem only to be given the run around. Is this model one of those cheap replaceable ones that rattles it self apart after (X) years? As I stated earlier, I'm not touching it, I'm just looking for some answers. I do thank you for any help you could give me. It's greatly appreciated. Dave-0 |
|
|
|
|
|
#2 |
|
Pro
Trade: plumbing and heating
Join Date: May 2005
Location: MA
Posts: 295
|
Re: Carrier 48ss
I'm not an AC tech but it sounds like the unit is to small for you're shop. If it was never great from the beginning it may not have been properly sized. You have to take into account the amount of BTU's that you're cooking/baking is giving off.
|
|
|
|
|
|
#3 | |
|
Registered User
Trade: Construction
Join Date: Jun 2005
Posts: 2
|
Re: Carrier 48ssQuote:
|
|
|
|
|
|
|
#4 |
|
The Doctor is In!
Trade: HVAC owner
Join Date: Apr 2004
Location: Kansas
Posts: 227
|
Re: Carrier 48ss
Square footage means nothing. Find you a contractor that will do a heat load calculation that will take into account the appliances and their usage for sizing. As for the 48SS, they are an ok unit and I have many installed in various applications. That being said they are the bottom end as far as the product line ie the cheapest available. That doesn't affect their ability to perform or function as they should. If properly sized, installed, and cared for they will do just as well as the top end models. There are no recalls of this product or any service bulletins/upgrades. If you have had that many compressor failures, I would begin to think that the company didn't properly evacuate the system and replace filter driers on the first and consecutive compressors. They also seemed to have not determined the cause of the first compressor failure (power surge, brown outs, dropped phase etc). I would start looking for a new company and new system or systems if needed.
|
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Carrier 48SS Heat Exchanger Rupture | bengineer | HVAC | 15 | 11-27-2009 02:02 PM |
| Insurance carrier in NY? | Rayman | Business | 0 | 04-24-2007 04:13 PM |
| Carrier Model 58MXA banging/clicking noise on start up | gsevans | HVAC | 5 | 01-03-2007 10:41 PM |
| American Standard or Carrier? | Bigvree | HVAC | 4 | 02-03-2006 08:10 PM |
| carrier 58wav not igniting | puppielover | HVAC | 3 | 01-23-2006 05:55 PM |
| Go to Page... |