Thread Tools | Search this Thread | Display Modes |
|
|
#1 |
|
jakeri
Guest
Posts: n/a
|
Amer Standard Variable Speed
I have 15 SEER Variable Speed AS units that were installed last year (gas furnace). My installation company ran 5 conductor wire to the thermostat (TH8110U). Can the two stage heat and variable speed blower work properly with only 5 wires? Two terminals are jumped together at the T stat
|
|
|
|
#2 |
|
mdshunk
Guest
Posts: n/a
|
Re: Amer Standard Variable Speed
Yes....
The variable speed is a function of the ECM motor in these units, and has nothing to do with the stat or the stat cable. 5 conductors... sure.... Rh and Rc jumpered. Y,G, W1, W2. That's 5 conductors. I'm assuming this stat takes a battery? |
|
![]() |