Xenon Pucks And Wall Cabinet Space?


I'd like to put xenon pucks into new glass front kitchen wall cabinets.

The cabinets will be 5 inches from the ceiling and have a trim and crown moulding on the top extending from the wall cabinet to the ceiling. Since I am renovating my kitchen, the drywall has been removed and I have the ability to run romex cable anywhere.
How is this usually wired if there isn't an open space on top of the cabinets?

My question:

Is it ok to place the transformer on top of the cabinets in the 5" of space I have - behind the crown moulding?

If this is ok, I assume it should be hardwired and not plugged into a new recepticle in this small space right? However, all the pucks I can find have the transformers plugged in.

Thanks


Last edited by LI Hardwood Guy; 02-17-2005 at 05:10 PM.
LI Hardwood Guy is offline  
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Old 02-17-2005, 07:47 PM   #2
Electrical Contractor
 
Speedy Petey's Avatar
 
Trade: Electrical
Join Date: Sep 2003
Location: NY State
Posts: 2,179

Re: Xenon Pucks And Wall Cabinet Space?


The most "legal" way to do this is to run CL2 low-voltage wire (ok for in wall use) to each light. Run this up into the attic and splice them all to the transformer secondary wire. Install a switched receptacle in an accessible spot and plug the transformer in.
__________________

Speedy Petey is online now  
Old 02-17-2005, 08:27 PM   #3
New Guy
 
LI Hardwood Guy's Avatar
 
Join Date: Dec 2004
Posts: 23

Re: Xenon Pucks And Wall Cabinet Space?


Quote:
Originally Posted by Speedy Petey
The most "legal" way to do this is to run CL2 low-voltage wire (ok for in wall use) to each light.
Thanks for the advice.

What guage wire CL2 should I use for 18W pucks?
And would a long length of this wire affect the current/lights?
LI Hardwood Guy is offline  
Old 02-17-2005, 08:57 PM   #4
Electrical Contractor
 
Speedy Petey's Avatar
 
Trade: Electrical
Join Date: Sep 2003
Location: NY State
Posts: 2,179

Re: Xenon Pucks And Wall Cabinet Space?


If you "daisy chain" them go with 14 or 16 gauge. If the length is long (+50'), go at least 14.
__________________

Speedy Petey is online now  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Join Now... It's Fast and FREE!

Privacy Badge
I am a professional contractor
I am a DIY Homeowner
ContractorTalk.com is for
PROFESSIONAL CONTRACTORS ONLY!

At ContractorTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?