#21 | |
|
And I do electrical, too!
Trade: DEFENDER OF FREEDOM! ADVOCATE OF LIBERTY!
Join Date: Jan 2009
Location: Iowa
Posts: 5,409
|
Re: Romex Splice And Tap Kit??Quote:
I pull out just enough to make it up in the box. No need to pull any slack up.
__________________
Site : the area or exact plot of ground on which anything is, has been, or is to be located. Sight : The power or faculty of seeing; perception of objects by use of the eyes; vision. Cite : To mention in support, proof, or confirmation; refer to as an example. |
|
|
|
|
|
|
#22 | |
|
I builds'em
Trade: Renovations & Decks
Join Date: Jun 2008
Location: Vancouver, BC, Canada
Posts: 3,511
|
Re: Romex Splice And Tap Kit??Quote:
So, I'm assuming your inspectors have no issues with leaving those loops in the wall?
__________________
Ryan |
|
|
|
|
|
|
#23 | |
|
And I do electrical, too!
Trade: DEFENDER OF FREEDOM! ADVOCATE OF LIBERTY!
Join Date: Jan 2009
Location: Iowa
Posts: 5,409
|
Re: Romex Splice And Tap Kit??Quote:
There's no Code violation in it, so there's no issue with it.
__________________
Site : the area or exact plot of ground on which anything is, has been, or is to be located. Sight : The power or faculty of seeing; perception of objects by use of the eyes; vision. Cite : To mention in support, proof, or confirmation; refer to as an example. |
|
|
|
|
|
|
#24 |
|
Registered User
Trade: Electrical Contractor
Join Date: Jul 2009
Posts: 3
|
Re: Romex Splice And Tap Kit??
I do warranty work for a Home manufacutrer that uses this product. They DO FAIL. I replace them with a j- box under the home and do the splice the old fashion way. I could not imagine these buried in a wall or any other cavity, as they do "burnout" when they fail. They are like the plugs in the back of devices, good for a few years or more, but heat and fatigue with use. I put them in the same catagory as cut in devices that use no box, I would not let my kids sleep in a home having them.
|
|
|
|
|
|
#25 | |
|
Fentoozler
Trade: Professional Pie and Pastry Taster
Join Date: May 2007
Location: New Jersey
Posts: 5,585
|
Re: Romex Splice And Tap Kit??Quote:
I am unaware of any 110v+ voltage devices that can be installed w/o a box.
__________________
|
|
|
|
|
|
|
#26 | |
|
Pro
Trade: Professional Handyman
Join Date: Jul 2008
Location: S.E. PA
Posts: 563
|
Re: Romex Splice And Tap Kit??Quote:
![]() Think of the money you'll save! Boxes...we don't need no stinkin' boxes!
__________________
The cat box ain't gonna clean itself. |
|
|
|
|
|
|
#27 | |
|
And I do electrical, too!
Trade: DEFENDER OF FREEDOM! ADVOCATE OF LIBERTY!
Join Date: Jan 2009
Location: Iowa
Posts: 5,409
|
Re: Romex Splice And Tap Kit??Quote:
Now you are:
__________________
Site : the area or exact plot of ground on which anything is, has been, or is to be located. Sight : The power or faculty of seeing; perception of objects by use of the eyes; vision. Cite : To mention in support, proof, or confirmation; refer to as an example. |
|
|
|
|
|
|
#28 |
|
Fentoozler
Trade: Professional Pie and Pastry Taster
Join Date: May 2007
Location: New Jersey
Posts: 5,585
|
Re: Romex Splice And Tap Kit??
__________________
|
|
|
|
|
|
#29 |
|
Professional Instigator
Trade: Design Build Remodeling Contractor DC MD
Join Date: Nov 2007
Location: Washington, DC/ Maryland
Posts: 6,872
|
Re: Romex Splice And Tap Kit??
Yeah I need a link.
|
|
|
|
|
|
#30 |
|
And I do electrical, too!
Trade: DEFENDER OF FREEDOM! ADVOCATE OF LIBERTY!
Join Date: Jan 2009
Location: Iowa
Posts: 5,409
|
Re: Romex Splice And Tap Kit??
They're made by P&S, but they don't list them in their catalog.
__________________
Site : the area or exact plot of ground on which anything is, has been, or is to be located. Sight : The power or faculty of seeing; perception of objects by use of the eyes; vision. Cite : To mention in support, proof, or confirmation; refer to as an example. |
|
|
|
|
|
#31 | |
|
Fentoozler
Trade: Professional Pie and Pastry Taster
Join Date: May 2007
Location: New Jersey
Posts: 5,585
|
Re: Romex Splice And Tap Kit??Quote:
As they are in the "mobilehomepartsstore.com", would they be allowed in a conventional building?
__________________
|
|
|
|
|
|
|
#32 | |
|
And I do electrical, too!
Trade: DEFENDER OF FREEDOM! ADVOCATE OF LIBERTY!
Join Date: Jan 2009
Location: Iowa
Posts: 5,409
|
Re: Romex Splice And Tap Kit??Quote:
I find it interesting that the cheapest of anything is somehow magically rated 'for use in mobile homes'.
__________________
Site : the area or exact plot of ground on which anything is, has been, or is to be located. Sight : The power or faculty of seeing; perception of objects by use of the eyes; vision. Cite : To mention in support, proof, or confirmation; refer to as an example. |
|
|
|
|
|
|
#33 |
|
Registered User
Trade: Electrical Contractor
Join Date: Jul 2009
Posts: 3
|
Re: Romex Splice And Tap Kit??
The boxless devices have a high failure rate. Most Modular Home manufactures around here have stopped using them. The "Boxless" splices have begin to give us a lot of call backs as well. I don't forsee them being used much longer unles they are improved. I do warranty work for some manufactures in my area, so I have encountered many of these devices. I get a lot of service calls over these devices, in every case we eliminate them and use cut in box and standard device.
|
|
|
|
|
|
#34 |
|
Pro
Trade: Professional Handyman
Join Date: Jul 2008
Location: S.E. PA
Posts: 563
|
Re: Romex Splice And Tap Kit??So...still have to cut a hole, still have to connect wires... What is the supposed advantage of these?
__________________
The cat box ain't gonna clean itself. |
|
|
|
![]() |