Outlets in countertop
Anyone ever set an outlet into the surface of a kitchen countertop? I guess it would have to have some kind of cover in order to be code compliant in addition to being GFI protected, thanks GMOD.
__________________
|
|
|
Warning: The topics covered on this site include activities in which there exists the potential for serious injury
or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Join the #1 Contractor Forum Today - It's Totally Free!
ContractorTalk.com - Are you a Professional Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for contractors to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your trade is you'll find that ContractorTalk.com is a great community to join. Best of all it's totally free!
Join ContractorTalk.com - Click Here

|
10-31-2009, 01:31 PM
|
#2
|
|
Master Electrician
Trade:
Electrical
Join Date: Sep 2007
Location: Midwest
Posts: 381
|
Flush
Sorry
(5) Receptacle Outlet Location. Receptacle outlets shall be located above the countertop, but not more than 18 inches from the countertop surface. Receptacles shall not be installed in a face-up position in the work surfaces or countertops and they must not be located on the sides of cabinets.
I would never put them in anyhow even if someone asked me too. Things always get spilled on countertops. It would just be trouble in the long run.
|
|
|
10-31-2009, 02:43 PM
|
#3
|
|
Pro
Trade:
General, Electrical, and Plumbing Contractor
Join Date: Feb 2007
Location: Portland, OR & Eatonville, WA
Posts: 722
|
You have to use a pop up receptacles in counter tops like on islands, etc.
I saw a really nice new one in one of my trade magazine the other day, much better looking and a lower profile than most of them I have used or seen in the past. I'll have to find where I saw it and post a link.
|
|
|
|
The Following User Says Thank You to Kgmz For This Useful Post:
|
|
10-31-2009, 02:46 PM
|
#4
|
|
Cabinetmaker
Trade:
Cabinetmaker
Join Date: Oct 2006
Location: Netcong, NJ
Posts: 670
|
Bubbles Thweetie:   Just a question; What about all the outlets put into the sides of Island cabinets?
|
|
|
10-31-2009, 03:16 PM
|
#5
|
|
Electrical Contractor
Trade:
Electrical
Join Date: Sep 2003
Location: NY State
Posts: 1,952
|
Quote:
Originally Posted by skymaster
Bubbles Thweetie:   Just a question; What about all the outlets put into the sides of Island cabinets?
|
What about them? They are fine as long as they are less than 12" down from the top. Lower than that will not meet the dimensions for any required counter top receptacles.
__________________
|
|
|
11-01-2009, 06:08 PM
|
#6
|
|
Registered User
Trade:
Electrical apprentice
Join Date: Oct 2009
Location: Massachusetts
Posts: 1
|
I think that he is asking why are they allowed in the sides of island cabinets and not the other kitchen cabinets?
|
|
|
11-01-2009, 06:24 PM
|
#7
|
|
Master Electrician
Trade:
Electrical
Join Date: Sep 2007
Location: Midwest
Posts: 381
|
cabinet
An inspector told me a while ago. It's what you call the area that's makes the difference. One cabinet is above the counter and one has a counter on top of it. Or maybe since it's called an island it's not really a cabinet even though it really is. Sometimes it can get confusing. I just passed a big job where I was wondering how they would enforce the afci rule. A 26 room frat house with 26 rooms with a bath and micro but not permanant kitchen facilities. It was classified an R2 which puts it in same category as motels/hotels/nursing homes/ etc... hence we didnt need afci's in the bedrooms in that instance since they were not considered dwelling units.
|
|
|
11-01-2009, 06:32 PM
|
#8
|
|
Pro
Trade:
Painting in Utah
Join Date: Jan 2006
Location: Southern Utah
Posts: 621
|
|
|
|
11-01-2009, 06:48 PM
|
#9
|
|
Pro
Trade:
General, Electrical, and Plumbing Contractor
Join Date: Feb 2007
Location: Portland, OR & Eatonville, WA
Posts: 722
|
RCPainting that is the same type of outlet I saw in a different picture in a trade mag.
Gene, found out who makes the outlet, its made by Mockett. I have used Mockett's before but they were a little uglier than this one, and they also have some other new ones that are better than what they had in the past.
http://www.mockett.com
|
|
|
11-01-2009, 07:13 PM
|
#10
|
|
Master Electrician
Trade:
Electrical
Join Date: Sep 2007
Location: Midwest
Posts: 381
|
nice
yeah. that's not face up so that should pass. That's pretty nice looking. Thanks for link.
|
|
|
|
The Following User Says Thank You to Bubbles For This Useful Post:
|
|
11-01-2009, 07:33 PM
|
#11
|
|
ampman
Trade:
providing pathways for electrons and protons
Join Date: Apr 2009
Location: central florida
Posts: 733
|
Quote:
Originally Posted by skymaster
Bubbles Thweetie:   Just a question; What about all the outlets put into the sides of Island cabinets?
|
not sure what you mean here
__________________
T.Boone Pickens " by buying foreign oil we are funding both sides of the war "
|
|
|
11-01-2009, 07:34 PM
|
#12
|
|
ampman
Trade:
providing pathways for electrons and protons
Join Date: Apr 2009
Location: central florida
Posts: 733
|
Quote:
Originally Posted by RCPainting
|
now that is cool when i redo my kitchen we will have these
__________________
T.Boone Pickens " by buying foreign oil we are funding both sides of the war "
|
|
|
11-01-2009, 07:37 PM
|
#13
|
|
ampman
Trade:
providing pathways for electrons and protons
Join Date: Apr 2009
Location: central florida
Posts: 733
|
how do you get these to pop up
__________________
T.Boone Pickens " by buying foreign oil we are funding both sides of the war "
|
|
|
| Thread Tools |
Search this Thread |
|
|
|
| Display Modes |
Rate This Thread |
Linear Mode
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
|
|