Electrical Code Question


Two codes questions that I suspect will be easy for someone to answer!

1) Do all the receptacles in a bathroom have to be GFCI or just the ones near the sink?

2) Along with that, are receptacles required anywhere in the bathroom other than near the sink. I know they can't be in the shower space, tub space or in the toilet , but I have a wall run of about 8' opposite the wall that will have the shower and vanity, so I didn't know if I'll need outlets there.

2) Are outlets required in a walk-in closet?

Thanks!

Kevin

Kevin75 is offline  
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Old 11-23-2007, 04:13 PM   #2
Electrical Contractor
 
Speedy Petey's Avatar
 
Trade: Electrical
Join Date: Sep 2003
Location: NY State
Posts: 2,179

Re: Electrical Code Question


1) ALL bath receptacles require GFI protection. 210.8(A)(1)

2) Only vanity/sink area receptacles are required. Others are optional with the limitations you described. 210.52(D)

3) No. None required.
__________________

Speedy Petey is offline  
Old 11-23-2007, 04:34 PM   #3
Newbie
 
Kevin75's Avatar
 
Trade: Home Renovations
Join Date: Oct 2007
Location: Dillsburg, PA
Posts: 97

Re: Electrical Code Question


Excellent...thank you!
Kevin75 is offline  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Residential code question bujaly General Discussion 14 09-25-2007 07:14 PM
Electrical Newb Question myshtern Electrical 51 09-19-2007 07:01 PM
Code question Mike Finley General Discussion 4 01-31-2007 08:16 PM
Code question dwasifar Electrical 87 01-21-2007 10:42 PM
Question regarding surplus electrical material solcam Electrical 2 07-25-2006 06:31 PM

Join Now... It's Fast and FREE!

Privacy Badge
I am a professional contractor
I am a DIY Homeowner
ContractorTalk.com is for
PROFESSIONAL CONTRACTORS ONLY!

At ContractorTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?