Blown (thrown) In Insulation And Ceiling Cans?
How do you deal with recessed ceiling cans when throwing insulation between the ceiling joists? Do they have to be protected?
__________________
Carpentry and Woodworking - Chicago / North Shore - Ted's Carpentry "I don't know everything but at least I think I do, and that's what really matters."
|
|
|
|
|
|
#2 |
|
DGR,IABD
Trade: Electrical; Commercial and Residential Service
Join Date: Mar 2005
Location: Central PA
Posts: 9,680
|
Re: Blown (thrown) In Insulation And Ceiling Cans?
IC rated cans can be insulated up against. Non-IC rated cans need 3" of clearance around the sides. I have no idea how this is accomplished with blown insulation.
|
|
|
|
|
|
#3 |
|
Yet another carpenter
Trade: Carpenter Woodworker
Join Date: Jan 2007
Location: Chicago, IL
Posts: 291
|
Re: Blown (thrown) In Insulation And Ceiling Cans?
I'm sure these are non-IC rated as they're pretty cheap. I can see what's available at HD to cut into baffles, or just make some from cardboard. Any other ideas, anyone?
__________________
Carpentry and Woodworking - Chicago / North Shore - Ted's Carpentry "I don't know everything but at least I think I do, and that's what really matters."
|
|
|
|
|
|
#4 | |
|
Member
Trade: Electrician
Join Date: Jan 2007
Posts: 85
|
Re: Blown (thrown) In Insulation And Ceiling Cans?Quote:
Funny you said that my doctor remodel had his entire first floor while he slept in the basement The GC hired a non-lic elec. company the elec put 16 non-ic in the kitchen and 31 non-ic in the living room One day he smell odor call 911 fireman told him the smell like overheated light fixture The fire marshall pass on the report to the chief elec inspector when he went to inspect it more thoroughly found that insulation was burning told him to get a lic elec.to replace all the light fixture When he heard of my price to do that along with (4) other elec company bids He call the inspector back the inspector told him to call a sheet medal company and put a medal cover over each and every fixture, for the grand total of 15.00 per fixture |
|
|
|
|
|
|
#5 | |
|
Pro
Trade: Electrical contractor/General contractor/ ICC certified electrical inspector
Join Date: Dec 2006
Posts: 211
|
Re: Blown (thrown) In Insulation And Ceiling Cans?Quote:
Look into the can and it will say I C Rated if it is. Just because it came from HD doesn't mean that it isn't I C rated. 1/2'' sheet rock box works around them also quick to put in. |
|
|
|
|
|
|
#6 |
|
Pro
Trade: Electrical contractor/General contractor/ ICC certified electrical inspector
Join Date: Dec 2006
Posts: 211
|
Re: Blown (thrown) In Insulation And Ceiling Cans?
Might want to see if the inspector is going to require "air-tight" as well.
|
|
|
|
|
|
#7 |
|
Pro
Trade: Electrician
Join Date: Mar 2006
Location: Bucks County, PA
Posts: 320
|
Re: Blown (thrown) In Insulation And Ceiling Cans?
I just built some boxes out of fiberglass duct board, which was leftover from the hvac guy. Looked good. itchy stuff though....Aluminum flashing works well to. Non ic must be insulated overtop in this area. gone are the days of just pulling the insulation away 3"
|
|
|
|
![]() |