50 Hertz Appliances
I have a potential client who wants to bring her washer & dryer from overseas. I think the appliances run on 50 hertz. I told her I would need to check with the manufacturer to see if running them here would be persmissable. I am guessing not. I meet with her tomorrow (10/3)
Any thoughts on this?
__________________
220...221...whatever it takes!
|
|
|
Warning: The topics covered on this site include activities in which there exists the potential for serious injury
or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!
Join the #1 Contractor Forum Today - It's Totally Free!
ContractorTalk.com - Are you a Professional Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for contractors to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your trade is you'll find that ContractorTalk.com is a great community to join. Best of all it's totally free!
Join ContractorTalk.com - Click Here

|
10-02-2009, 03:16 PM
|
#2
|
|
Internet Creep
Trade:
Kitchen/Bath Remodeling, Tile
Join Date: Oct 2007
Location: Will County, Illinois
Posts: 1,190
|
Tell her it hurts you to inform her they won't work
__________________
"If you're good at something, never do it for free."
|
|
|
|
The Following User Says Thank You to angus242 For This Useful Post:
|
|
10-02-2009, 03:39 PM
|
#3
|
|
ampman
Trade:
providing pathways for electrons and protons
Join Date: Apr 2009
Location: central florida
Posts: 733
|
the voltage might be different also
__________________
T.Boone Pickens " by buying foreign oil we are funding both sides of the war "
|
|
|
10-02-2009, 03:42 PM
|
#4
|
|
Pro
Trade:
Licensed Electrical Contractor and Remodeler
Join Date: Sep 2009
Location: Chicago Suburbs
Posts: 700
|
Could be. I know the cord will have to be changed to a NEMA plug too.
I cant imagine why they would want to ship them all the way over here.
__________________
220...221...whatever it takes!
|
|
|
10-02-2009, 03:47 PM
|
#5
|
|
Electron Flow Manipulator
Trade:
Electrons for cash
Join Date: Jan 2009
Location: Iowa
Posts: 1,440
|
Sell her a frequency converter.
__________________
Age is just a number but mine is unlisted.
|
|
|
10-02-2009, 03:50 PM
|
#6
|
|
Pro
Trade:
Licensed Electrical Contractor and Remodeler
Join Date: Sep 2009
Location: Chicago Suburbs
Posts: 700
|
Thanks Sparky-I've never run across this before. Will the supply house usually carry these?
__________________
220...221...whatever it takes!
|
|
|
10-02-2009, 03:52 PM
|
#7
|
|
Internet Creep
Trade:
Kitchen/Bath Remodeling, Tile
Join Date: Oct 2007
Location: Will County, Illinois
Posts: 1,190
|
Just looked up a Bosch washer from the UK:
Nominal voltage 220-240 V, 50 Hz
Nominal current 10 A
Nominal power 2,300 W
__________________
"If you're good at something, never do it for free."
|
|
|
10-02-2009, 06:01 PM
|
#8
|
|
Pro
Trade:
Licensed Electrical Contractor and Remodeler
Join Date: Sep 2009
Location: Chicago Suburbs
Posts: 700
|
OK sparky, I think you got me. I followed your advice and did a little research and I think you know the result. But I may still try to sell her one!
__________________
220...221...whatever it takes!
Last edited by rselectric1; 10-02-2009 at 06:53 PM.
|
|
|
10-02-2009, 07:54 PM
|
#9
|
|
Pro
Trade:
Electrical
Join Date: May 2008
Location: Central Texas
Posts: 411
|
Quote:
Originally Posted by 480sparky
Sell her a frequency converter. 
|
Maybe the "whole house" model 
|
|
|
10-02-2009, 08:12 PM
|
#10
|
|
Pro
Trade:
Builder/Remodeler
Join Date: Jul 2007
Location: Indianapolis, Indiana
Posts: 2,064
|
Motors are typically designed for a specific frequency:
http://www.eng-tips.com/faqs.cfm?fid=1224
Even if you convert the voltage... it's still not a good idea.
|
|
|
10-02-2009, 08:49 PM
|
#11
|
|
Pro
Trade:
Licensed Electrical Contractor and Remodeler
Join Date: Sep 2009
Location: Chicago Suburbs
Posts: 700
|
Thanks Chris-You gave me the link and the answer I was looking for.
__________________
220...221...whatever it takes!
|
|
|
10-22-2009, 05:11 PM
|
#12
|
|
Pro
Trade:
contracts/negotiations
Join Date: Nov 2007
Posts: 170
|
Not unless they're from Japan where many appliances are made 50/60Hz due to the fact they use both frequencies domestically. Even then, induction motor equipped appliances rated for 50/60 Hz don't always perform the same. Refrigeration machinery provide less power. Other devices might work just fine, but require changing belt positions.
Microwave ovens, things with induction motor and alarm clocks(many don't have crystals, they use power line as time base) are typically frequency specific.
|
|
|
| Thread Tools |
Search this Thread |
|
|
|
| Display Modes |
Rate This Thread |
Linear Mode
|
|
Posting Rules
|
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts
HTML code is Off
|
|
|
|
|