Thread Tools | Search this Thread | Display Modes |
|
|
#1 |
|
General Contractor
Trade: General Contractor
Join Date: Apr 2006
Posts: 33
|
Screws And Spacing For Overhead Drywall?
I have a customer working me over about the number of screws in the ceiling on his drywall. He says that it must be screwed every 4 inches or it will fail. We do it basically every 20 over the length on every joist which is on 16 inch centers. Am I wrong for telling him I'm in good shape on this. It just doesn't seem to be an issue.
thanks for the help paul |
|
|
|
|
|
#2 |
|
Pro
Trade: manager of excavation division
Join Date: Dec 2005
Location: danbury,ct.
Posts: 3,660
|
Re: Screws And Spacing For Overhead Drywall?
I'm like old school, but nail ends like every 8" and on the other joists put a nail on each edge and then (3) groups of 2 nails spaced about 2 " apart.
Whats with 20?
__________________
___"Remember You Never Get A Second Chance To Make A First Impression"______________________ Joe |
|
|
|
|
|
#3 |
|
Custom Builder
|
Re: Screws And Spacing For Overhead Drywall?
4 in the field on the walls, 6 in the field on the ceiling. Groups of 2 as jmic mentioned.
Bob
__________________
Bob |
|
|
|
|
|
#4 |
|
Pro
Trade: Residential Contractor
Join Date: Feb 2004
Location: Jensen Beach, FL
Posts: 10,475
|
Re: Screws And Spacing For Overhead Drywall?
Give the dude what he wants. How much extra is it going to cost you?
A happy customer is a paying and repeat customer. I don't mind saying that I was a PITA when I had my new roof installed. I'm in hurricaneville, hit 3 times in 2 yrs. I insisted that everything was to Miami-Dade High Velocity Wind Code even though I'm in a zone 3 area. I was also a PITA here, I'm a remod, not a roofer. Tom (aka Grumpy) was a major help as were some others. Tip of the hat here. The upshot is that everything was done to my specs. and I'm a happy camper knowing that. The customer is always right. Maybe a PITA, but right just the same.
__________________
You can't solve you're problems with the same level of thinking that created the problems. Albert Einstein |
|
|
|
|
|
#5 |
|
Pro
Trade: Licensed Colorado electrician, licensed B-1 GC
Join Date: Jul 2005
Location: Colorado Front Range
Posts: 2,604
|
Re: Screws And Spacing For Overhead Drywall?
To many screws can break the sheet. That's my opinion but I think I may be right this time.
|
|
|
|
|
|
#6 |
|
Chief Toilet Mover
Trade: Bathroom Remodeling
Join Date: Apr 2004
Location: Littleton, Colorado
Posts: 14,078
|
Re: Screws And Spacing For Overhead Drywall?
The way I have always done it for ceilings is 12 inches in the field, 8 inches on the edges, screws only no nails. Float the corners. You can also use a construction adhesive for extra piece of mind.
Like Teetor says sometimes it's just easier to keep the customer happy, but I'm also of the mindset that unless there were conditions preset from the customer before the job starts that you acknowledge, accepted and added into your bill for the extra time needed to accomplish them, this type of micro management is not going to fly. The customer hired you as the pro, he has to have trust in what you do, I don't like the idea of giving up that position of authority as the professional by giving into customers unwarranted worries that might tend to keep snowballing. But that is a fine line you will have to walk. |
|
|
|
|
|
#7 |
|
Construction Estimator
Trade: Estimator
Join Date: Jun 2006
Location: Orlando Florida
Posts: 279
|
Re: Screws And Spacing For Overhead Drywall?
Mike is right! 8" edges 12" in field. This is the guidline from all major drywall manufacturers. Glue won't hurt either.
Dave |
|
|
|
|
|
#8 |
|
Brian
Trade: Complete Builder and Remodeler
Join Date: Jun 2006
Location: Indianapolis, IN
Posts: 6
|
Re: Screws And Spacing For Overhead Drywall?
By current building code for new construction in Indianapolis (in fact, it's the newest standard that was revised the beginning of this year), and what all 3 new home builders require that we do work is as follows. Nails around the perimeter of the sheet only. Screws to be installed on every joist. On standard 4' board, 3 screws are required. On 54" board, 4 screws are required. Hope this helps.
|
|
|
|
|
|
#9 | |
|
Pro
Trade: Lic. GC/Remodr - Commercial/Residential/Industrial
Join Date: Mar 2006
Location: New England
Posts: 2,702
|
Re: Screws And Spacing For Overhead Drywall?Quote:
Same measurements with the building codes here (Printed right in the back under the fasteners tables). Only difference from that standard is: More screws required with 5/8" SR and more with Plaster application (More weight being carried over the surface of the Sheet)
__________________
- Build Well - |
|
|
|
|
|
|
#10 |
|
Construction Estimator
Trade: Estimator
Join Date: Jun 2006
Location: Orlando Florida
Posts: 279
|
Re: Screws And Spacing For Overhead Drywall?
Brian,
I see you are from Indy. I just left the area 2 years ago. What the market like there these days. Who are you buying your rock from..V-line,IDS, R&W, Magnum? Dave
__________________
A buck a foot is not an estimate! It's a crap shoot! |
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
| Go to Page... |