#1 |
|
Hammer
Trade: Home Improvements Bathroom kitchen remodeling fini
Join Date: Oct 2007
Location: Macomb County, MI
Posts: 39
|
Improper Venting
Looked at a full bath remodel, to include new exhaust fan yesterday, 12 year old home. Upon inspection noticed the existing fan was vented into attic.
When i explained to the customer that this is a problem and that the builder had done this improperly and would need correction, I was told that they were the builder and that the building inspector told him that this is how it was to be done . I explained the reasons for exhausting to the outside and told him I would include fixing the problem. Has code changed in the recent past? Or is the inspector an idiot. Or maybe H.O. trying to cover. It did pass all inspections. Your thoughts?
__________________
Chuck Bittner American Home Improvements www.AHomeProNow.com www.American-HomeImprovements.com |
|
|
|
|
|
#2 | |
|
Registered User
Trade: Handyman/ Carpenter
Join Date: Nov 2009
Location: Rowley MA 01969
Posts: 12
|
Re: Improper VentingQuote:
I'm from Rowley,MA and that would not get by any of the inspectors here. John Radziewicz Johns Handyman Service |
|
|
|
|
|
|
#3 |
|
Curmudgeon
Trade: carpentry/remodeling/"Yes M'am we do"
Join Date: Apr 2006
Location: Beech Grove, Indiana, Birthplace of the "King of Cool"
Posts: 11,707
|
Re: Improper Venting
Can't look into HO's soul, or
read inspector's mind. ![]() Can say, the vent is wrong.
__________________
Put your location in your profile! (Sorry....it seems there really are dumb questions) |
|
|
|
|
|
#4 |
|
Member
Trade: Residential GC
Join Date: Nov 2009
Location: Boulder CO
Posts: 33
|
Re: Improper Venting
My guess is the homowner is making excuses for their lack of knowledge. Maybe they had the fan installed but not vented yet when it was inspected. With a whole house to inspect I have seen inspectors in and out in a matter of 15 minutes. Could have had an inspector who just didn't pick it up.
But it's really not a big deal. Just vent it through the roof. 1hr of work. |
|
|
|
|
|
#5 |
|
Pro
Trade: Residential Remodeling
Join Date: Jan 2008
Location: Suwanee, Georgia
Posts: 380
|
Re: Improper Venting
Here in Georgia that was allowed for a long time. Not sure when the code changed but I think it has only been in the last ten years. When I did new construction we did vent outside but I have run across many homes where the bath fans were vented to the attic.
Of course the humidity is usually so high here in Atlanta whats a little more .
|
|
|
|
|
|
#6 |
|
Pro
Trade: siding
Join Date: Mar 2007
Location: west milford n.j.
Posts: 8,851
|
Re: Improper Venting
ive seen that here too,not fof years tho,thats something like the fan installer says the sider installs the vent,sider says the roofer does it
roofer says.....
__________________
Tom |
|
|
|
|
|
#7 |
|
Thom
Trade: General Contractor/Homebuilder
Join Date: Nov 2006
Location: Albuquerque NM
Posts: 3,194
|
Re: Improper Venting
the key here is "they were the builder".
The tinners install the hvac rough, get their stuff installed then leave. The electrician installs the fart fans, but the venting inspection has already been done. That's why the GC gets the fart fans installed (but not wired) prior to the tinners showing up. In this case, the GC was ignorant. |
|
|
|
|
|
#8 |
|
Pro
Trade: General Contractor
Join Date: Jun 2009
Location: Stafford, VA
Posts: 318
|
Re: Improper Venting
IRC M1506.2 Recirculation of air.
Exhaust air from bathrooms and toilet rooms shall not be recirculated within a residence or to another dwelling unit. May not have been code when they built it but it is code now. If you are doing a complete gut and remodel, I would imagine they will require it to be properly vented now. Besides that you can inform them of the cost to replace insulation, drywall, and mold remediation caused by the moisture they are venting into their attic. |
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Venting weather deck over heated space. | Nailpuller | Construction | 3 | 08-02-2011 02:54 PM |
| new venting through a chimney. | flashheatingand | HVAC | 3 | 09-07-2009 02:52 PM |
| Does roof venting really prolong shingle life? | willworkforbeer | Roofing | 32 | 06-24-2009 05:23 PM |
| Venting! + Need advice from other GC's | D.A.S.Anthony | Business | 29 | 01-29-2009 09:03 AM |
| Dryer/HVAC venting | Kevin75 | HVAC | 17 | 08-28-2008 08:09 PM |
| Go to Page... |