Thread Tools | Search this Thread | Display Modes |
|
|
#1 |
|
Pro
Trade: remodeling/specializing in kitchen & baths
Join Date: Dec 2005
Location: midwest
Posts: 660
|
Rafter Lengths
planning a rm addn w/ a hip roof, 8/12 pitch,18wx20d. rafters 16"oc, 12" oh
are the hip rafters 2x8 or 2x10? field rafters are 2x6. length? common rafter length? i was never the cut man on a roof so i'm winging this matl list, would appreaciate any help. thanks |
|
|
|
|
|
#2 |
|
Pro
Trade: Residential custom home builder
Join Date: Jan 2006
Location: St. Cloud, MN, USA
Posts: 177
|
Re: Rafter Lengths
The pitch factor for an 8:12 is 1.20, so your common rafter length is total run (building centerline to outside of wall plus soffit depth) x 1.2.
2x8s should be plenty for the hips. In theory, the roof structure carries the hip, and not vice-versa.
__________________
Clint - carpenter, coordinator, webmaster |
|
|
|
![]() |