2*6 Studs The Norm?

 
Thread Tools Search this Thread Display Modes
Old 11-08-2007, 07:19 PM   #1
Average Joe
 
Heritage's Avatar
 
Trade: D/B, Management, Consulting, Contracting.
Join Date: Mar 2007
Location: Toronto
Posts: 1,181

2*6 Studs The Norm?


I'm a GC. I recently hired a new framer for one of my jobs. He tells me that all new devolopment houses are using 2*6 studs....?

He claims it's code, 10 years old.

Have I been living under a rock? New code on studs (bearing and non-bearing) is 2*6? (Residential 2 storey)

It makes absolutely no sense to me. A)there isn't much the 2*6 can do that the 2*4 can't (stud-wise). B) I seriously doubt developers are going to dish out an extra $1 per stud (ball-park).

He also claims all window opening headers are supposed to be 2*8...?

Is this guy from the twilight zone...or am I?

What's the verdict?
1)Can his arse
2)Tell him he was wrong, be a nice guy and move on.
3)I'm the idiot and I need to be up on my codes some more.

__________________
Toronto General Contractor-Renovation Blog-Contractor on Facebook-Renovation on twitter-Contractor Youtube
Quote:
Originally Posted by rex View Post
i get high with my left hand.....
Heritage is offline  
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Old 11-08-2007, 07:26 PM   #2
Pro
 
joasis's Avatar
 
Trade: General Contractor
Join Date: Mar 2006
Location: Hennessey, Oklahoma
Posts: 6,057

Re: 2*6 Studs The Norm?


The 6 inch depth allows more insulation, ....you are kidding, right? I don't know what codes you follow up north, but the energy code requirements of the IRC are hard to meet with 2X4 walls...but it can be done. The cost of going to 2X6's will not break the bank.
__________________
Ladwig Construction
Hennessey, Oklahoma
405 853 1563

Ladwig Insulation & Construction Services
Serving Oklahoma Statewide
joasis is offline  
Old 11-08-2007, 07:31 PM   #3
Curmudgeon
 
neolitic's Avatar
 
Trade: carpentry/remodeling/"Yes M'am we do"
Join Date: Apr 2006
Location: Beech Grove, Indiana, Birthplace of the "King of Cool"
Posts: 11,707

Re: 2*6 Studs The Norm?


Here no one cares how you get to R-19.
R-5 sheathing, R13 batts, drywall, and ANY siding makes it.
__________________
Put your location in your profile!
(Sorry....it seems there really are dumb questions)
neolitic is offline  
Old 11-08-2007, 07:31 PM   #4
Pro
 
send_it_all's Avatar
 
Trade: general contractor/ remodeling
Join Date: Apr 2007
Location: Orange County, Ca.
Posts: 1,989
Send a message via Yahoo to send_it_all

Re: 2*6 Studs The Norm?


What about option #4?...build according to plans.
send_it_all is offline  
Old 11-08-2007, 07:31 PM   #5
Doofenshmirtz Evil Inc.
 
JumboJack's Avatar
 
Trade: GC
Join Date: Aug 2007
Location: Lakewood CA.
Posts: 3,660

Re: 2*6 Studs The Norm?


Quote:
Originally Posted by Heritage View Post
I'm a GC. I recently hired a new framer for one of my jobs. He tells me that all new devolopment houses are using 2*6 studs....?

He claims it's code, 10 years old.

Have I been living under a rock? New code on studs (bearing and non-bearing) is 2*6? (Residential 2 storey)

It makes absolutely no sense to me. A)there isn't much the 2*6 can do that the 2*4 can't (stud-wise). B) I seriously doubt developers are going to dish out an extra $1 per stud (ball-park).

He also claims all window opening headers are supposed to be 2*8...?

Is this guy from the twilight zone...or am I?

What's the verdict?
1)Can his arse
2)Tell him he was wrong, be a nice guy and move on.
3)I'm the idiot and I need to be up on my codes some more.
Like joasis said you can ger r19 insulation in.As far as being required it is not in Cali..I know that is hotter climates ie:AZ,NV it is pretty common practice to use 2x6's for all the outside walls but I doubt they use them on inside.
__________________
in texas with framing and cornish people will do it for 3.00 a foot. What do yall think about that? Just laber
JumboJack is offline  
Old 11-08-2007, 07:33 PM   #6
Pro
 
send_it_all's Avatar
 
Trade: general contractor/ remodeling
Join Date: Apr 2007
Location: Orange County, Ca.
Posts: 1,989
Send a message via Yahoo to send_it_all

Re: 2*6 Studs The Norm?


Quote:
Originally Posted by JumboJack View Post
Like joasis said you can ger r19 insulation in.As far as being required it is not in Cali..I know that is hotter climates ie:AZ,NV it is pretty common practice to use 2x6's for all the outside walls but I doubt they use them on inside.
Just on walls that contain plumbing.
send_it_all is offline  
Old 11-08-2007, 07:33 PM   #7
Average Joe
 
Heritage's Avatar
 
Trade: D/B, Management, Consulting, Contracting.
Join Date: Mar 2007
Location: Toronto
Posts: 1,181

Re: 2*6 Studs The Norm?


No I'm not kidding. A 10" gap allows for even more insulation, heck let's go 12"?!

Is that seriously the code?

For how long now?

Why did he say "on all walls, interior and exterior".

You are pulling my leg huh Joasis? Why you
__________________
Toronto General Contractor-Renovation Blog-Contractor on Facebook-Renovation on twitter-Contractor Youtube
Quote:
Originally Posted by rex View Post
i get high with my left hand.....
Heritage is offline  
Old 11-08-2007, 07:39 PM   #8
Pro
 
Patrick's Avatar
 
Trade: Siding, Windows, Seamless Gutters, Metal Roofing
Join Date: Apr 2006
Posts: 2,761

Re: 2*6 Studs The Norm?


There is a neighborhood near me that dates to maybe the 50's or 60s all one story capes by the same builder, 2x3 walls!!!!!!!!!!
Patrick is offline  
Old 11-08-2007, 07:40 PM   #9
Pro
 
Joe Carola's Avatar
 
Trade: Framing Contractor
Join Date: Jun 2004
Location: Caldwell, New Jersey
Posts: 1,541

Re: 2*6 Studs The Norm?


Heritage,

It is not code. I frame some jobs with 2x6 and some with 2x4. It doesn't make a difference. Who drew your plans and who is this framer to tell you it is code and what you have to do on your job?

Why not just ask your building department?

Structurally wise you can build three stories with 2x4's.
__________________
Joe Carola
Joe Carola is offline  
Old 11-08-2007, 07:45 PM   #10
Member
 
Paul B's Avatar
 
Trade: Residential Contractor
Join Date: Mar 2007
Location: Maryland
Posts: 84

Re: 2*6 Studs The Norm?


There are a lot of homes built in the 50's that have 2x3 studs in Maryland. They also have cardboard for sheathing.
Paul B is offline  
Old 11-08-2007, 07:47 PM   #11
Curmudgeon
 
neolitic's Avatar
 
Trade: carpentry/remodeling/"Yes M'am we do"
Join Date: Apr 2006
Location: Beech Grove, Indiana, Birthplace of the "King of Cool"
Posts: 11,707

Re: 2*6 Studs The Norm?


Quote:
Originally Posted by Patrick View Post
There is a neighborhood near me that dates to maybe the 50's or 60s all one story capes by the same builder, 2x3 walls!!!!!!!!!!
Probably "National Homes", they have 2X2 partition walls too!
__________________
Put your location in your profile!
(Sorry....it seems there really are dumb questions)
neolitic is offline  
Old 11-08-2007, 07:52 PM   #12
Pro
 
Patrick's Avatar
 
Trade: Siding, Windows, Seamless Gutters, Metal Roofing
Join Date: Apr 2006
Posts: 2,761

Re: 2*6 Studs The Norm?


I found out about from a GC who gets calls from that neighborhood to add on second stories, and he says "no" and he loves the look on their faces when he tells them and explains what will be in order to add that second story
Patrick is offline  
Old 11-08-2007, 08:01 PM   #13
Pro
 
joasis's Avatar
 
Trade: General Contractor
Join Date: Mar 2006
Location: Hennessey, Oklahoma
Posts: 6,057

Re: 2*6 Studs The Norm?


Quote:
Originally Posted by Heritage View Post

You are pulling my leg huh Joasis? Why you
Simply because you sound like a suitcase contractor now....I don't know your business, but rest assured, as a GC, I know the codes for my area (IRC 2006/IBC 2006), and when a sub tells me something new, I verify it, because I need to know.

Not picking on you, but I would think you would be on top of your game.....the architect who draws my plans sometimes misses basic code requirements, and if I didn't know, then we could get flagged on an inspection. I know a guy who framed a full bath that was 35 sq/ft. Red flag! Had to install a pocket door to get the inspector to sign off....how do you feel about house wrap? Is it required? Insulation between the 2x's that you use for headers? Anchor bolts how far apart? Hurricane clips and strapping? See my point?
__________________
Ladwig Construction
Hennessey, Oklahoma
405 853 1563

Ladwig Insulation & Construction Services
Serving Oklahoma Statewide
joasis is offline  
Old 11-08-2007, 08:02 PM   #14
Pro
 
oldfrt's Avatar
 
Trade: Remodeling
Join Date: Oct 2007
Location: Northwest Connecticut
Posts: 2,039

Re: 2*6 Studs The Norm?


Before we can build a house here you have to submit a mech-check.
It's a measure of all the components of your home that have to do with heating.
It takes into consideration,insulation values,the U-Factors of all your windows as well as their sizes,furnace efficiency.sq.ft.of all exterior walls.ceiling heights,and doors.
So using 2x6 framing will help exterior wall efficiency,although it's not code.Some guys frame 2x4 and add the 1" insulation to the exterior.

As long as you pass the mech-check,your permit will be issued.
oldfrt is offline  
Old 11-08-2007, 08:02 PM   #15
Pro
 
Joe Carola's Avatar
 
Trade: Framing Contractor
Join Date: Jun 2004
Location: Caldwell, New Jersey
Posts: 1,541

Re: 2*6 Studs The Norm?


Quote:
Originally Posted by Patrick View Post
I found out about from a GC who gets calls from that neighborhood to add on second stories, and he says "no" and he loves the look on their faces when he tells them and explains what will be in order to add that second story
Patrick,

What is he telling them? What's the problem with adding a second story?
__________________
Joe Carola
Joe Carola is offline  
Old 11-08-2007, 08:06 PM   #16
Curmudgeon
 
neolitic's Avatar
 
Trade: carpentry/remodeling/"Yes M'am we do"
Join Date: Apr 2006
Location: Beech Grove, Indiana, Birthplace of the "King of Cool"
Posts: 11,707

Re: 2*6 Studs The Norm?


2X3's @24oc don't pass to support a second story here-a-bouts.
__________________
Put your location in your profile!
(Sorry....it seems there really are dumb questions)
neolitic is offline  
Old 11-08-2007, 08:08 PM   #17
Pro
 
curapa's Avatar
 
Trade: Carpentry / Fencing / Decks
Join Date: Oct 2007
Location: Savannah, Ga
Posts: 1,216

Re: 2*6 Studs The Norm?


2x4 here. I will step up to a 2x6 if I have wall height higher than 12'.. exterior only. I use 2x6 interior if I have pocket doors.
curapa is offline  
Old 11-08-2007, 08:09 PM   #18
Pro
 
Patrick's Avatar
 
Trade: Siding, Windows, Seamless Gutters, Metal Roofing
Join Date: Apr 2006
Posts: 2,761

Re: 2*6 Studs The Norm?


Joe, Im not a framer so I dont know if theres some other particulars besides just the 2x3's, but he insisted that as is,it would not have properly supported a second story.
Patrick is offline  
Old 11-08-2007, 08:23 PM   #19
Pro
 
Joe Carola's Avatar
 
Trade: Framing Contractor
Join Date: Jun 2004
Location: Caldwell, New Jersey
Posts: 1,541

Re: 2*6 Studs The Norm?


Quote:
Originally Posted by Patrick View Post
Joe, Im not a framer so I dont know if there's some other particulars besides just the 2x3's, but he insisted that as is,it would not have properly supported a second story.
Patrick,

Sorry, I didn't see the part about 2x3's. Never seen 2x3 walls before except for basement framing. Other than that, second story addition go up all the time above 2x4 walls without any questions.
__________________
Joe Carola
Joe Carola is offline  
Old 11-08-2007, 09:09 PM   #20
Pro
 
reveivl's Avatar
 
Trade: Renovations
Join Date: May 2005
Location: West Coast Canada
Posts: 1,716

Re: 2*6 Studs The Norm?


2x6 is the norm here for insulative, not structural, reasons. 2x8 headers over windows depends on the load/span calcs and nothing else. Though the common thing is to use 2x10 for all load bearing, because it will handle it, and you don't need to have 2x8 kicking around the site that is useless for anything else.

2x6 for plumbing walls often; pocket doors here are usually 2x4; supply plumbing cannot be in an exterior wall(!) (apparently because it gets so cold here on the wet coast). Hose bibs must be buried in an interior wall partition so they are protected from the once yearly cold snap we get. Yeah, right.
__________________
From where does knowledge come? If you need to know what is in a box, you could ask someone (not reliable), you could pray, (not useful), you can consult with the scripture (not helpful) or you could open the box (science)
reveivl is offline  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
cutting steel studs 25BRIAN General Discussion 28 05-22-2009 09:41 AM
Steel Studs in Bulkhead DSB_Const Framing 3 04-02-2009 03:12 PM
Fingerjointed Studs Milhaus Green Building 20 05-18-2007 11:12 AM
Metal Studs Vs. Wood Studs Towatei & Co. Drywall 7 05-12-2007 11:03 PM
Engineered studs? RYANINMICHIGAN Framing 7 03-22-2006 05:28 PM

Join Now... It's Fast and FREE!

Privacy Badge
I am a professional contractor
I am a DIY Homeowner
ContractorTalk.com is for
PROFESSIONAL CONTRACTORS ONLY!

At ContractorTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?