#1 |
|
Average Joe
Trade: D/B, Management, Consulting, Contracting.
Join Date: Mar 2007
Location: Toronto
Posts: 1,181
|
2*6 Studs The Norm?
I'm a GC. I recently hired a new framer for one of my jobs. He tells me that all new devolopment houses are using 2*6 studs....
?He claims it's code, 10 years old. Have I been living under a rock? New code on studs (bearing and non-bearing) is 2*6? (Residential 2 storey) It makes absolutely no sense to me. A)there isn't much the 2*6 can do that the 2*4 can't (stud-wise). B) I seriously doubt developers are going to dish out an extra $1 per stud (ball-park). He also claims all window opening headers are supposed to be 2*8... ?Is this guy from the twilight zone...or am I? What's the verdict? 1)Can his arse 2)Tell him he was wrong, be a nice guy and move on. 3)I'm the idiot and I need to be up on my codes some more. |
|
|
|
|
|
#2 |
|
Pro
Trade: General Contractor
Join Date: Mar 2006
Location: Hennessey, Oklahoma
Posts: 6,057
|
Re: 2*6 Studs The Norm?
The 6 inch depth allows more insulation, ....you are kidding, right? I don't know what codes you follow up north, but the energy code requirements of the IRC are hard to meet with 2X4 walls...but it can be done. The cost of going to 2X6's will not break the bank.
__________________
Ladwig Construction Hennessey, Oklahoma 405 853 1563 Ladwig Insulation & Construction Services Serving Oklahoma Statewide
|
|
|
|
|
|
#3 |
|
Curmudgeon
Trade: carpentry/remodeling/"Yes M'am we do"
Join Date: Apr 2006
Location: Beech Grove, Indiana, Birthplace of the "King of Cool"
Posts: 11,707
|
Re: 2*6 Studs The Norm?
Here no one cares how you get to R-19.
R-5 sheathing, R13 batts, drywall, and ANY siding makes it.
__________________
Put your location in your profile! (Sorry....it seems there really are dumb questions) |
|
|
|
|
|
#4 |
|
Pro
|
Re: 2*6 Studs The Norm?
What about option #4?...build according to plans.
|
|
|
|
|
|
#5 | |
|
Doofenshmirtz Evil Inc.
Trade: GC
Join Date: Aug 2007
Location: Lakewood CA.
Posts: 3,660
|
Re: 2*6 Studs The Norm?Quote:
__________________
in texas with framing and cornish people will do it for 3.00 a foot. What do yall think about that? Just laber |
|
|
|
|
|
|
#6 |
|
Pro
|
Re: 2*6 Studs The Norm?
Just on walls that contain plumbing.
|
|
|
|
|
|
#7 |
|
Average Joe
Trade: D/B, Management, Consulting, Contracting.
Join Date: Mar 2007
Location: Toronto
Posts: 1,181
|
Re: 2*6 Studs The Norm?
No I'm not kidding. A 10" gap allows for even more insulation, heck let's go 12"?!
Is that seriously the code? For how long now? Why did he say "on all walls, interior and exterior". You are pulling my leg huh Joasis? Why you
|
|
|
|
|
|
#8 |
|
Pro
Trade: Siding, Windows, Seamless Gutters, Metal Roofing
Join Date: Apr 2006
Posts: 2,761
|
Re: 2*6 Studs The Norm?
There is a neighborhood near me that dates to maybe the 50's or 60s all one story capes by the same builder, 2x3 walls!!!!!!!!!!
|
|
|
|
|
|
#9 |
|
Pro
Trade: Framing Contractor
Join Date: Jun 2004
Location: Caldwell, New Jersey
Posts: 1,541
|
Re: 2*6 Studs The Norm?
Heritage,
It is not code. I frame some jobs with 2x6 and some with 2x4. It doesn't make a difference. Who drew your plans and who is this framer to tell you it is code and what you have to do on your job? Why not just ask your building department? Structurally wise you can build three stories with 2x4's.
__________________
Joe Carola |
|
|
|
|
|
#10 |
|
Member
Trade: Residential Contractor
Join Date: Mar 2007
Location: Maryland
Posts: 84
|
Re: 2*6 Studs The Norm?
There are a lot of homes built in the 50's that have 2x3 studs in Maryland. They also have cardboard for sheathing.
|
|
|
|
|
|
#11 | |
|
Curmudgeon
Trade: carpentry/remodeling/"Yes M'am we do"
Join Date: Apr 2006
Location: Beech Grove, Indiana, Birthplace of the "King of Cool"
Posts: 11,707
|
Re: 2*6 Studs The Norm?Quote:
__________________
Put your location in your profile! (Sorry....it seems there really are dumb questions) |
|
|
|
|
|
|
#12 |
|
Pro
Trade: Siding, Windows, Seamless Gutters, Metal Roofing
Join Date: Apr 2006
Posts: 2,761
|
Re: 2*6 Studs The Norm?
I found out about from a GC who gets calls from that neighborhood to add on second stories, and he says "no" and he loves the look on their faces when he tells them and explains what will be in order to add that second story
|
|
|
|
|
|
#13 |
|
Pro
Trade: General Contractor
Join Date: Mar 2006
Location: Hennessey, Oklahoma
Posts: 6,057
|
Re: 2*6 Studs The Norm?
Simply because you sound like a suitcase contractor now....I don't know your business, but rest assured, as a GC, I know the codes for my area (IRC 2006/IBC 2006), and when a sub tells me something new, I verify it, because I need to know.
Not picking on you, but I would think you would be on top of your game.....the architect who draws my plans sometimes misses basic code requirements, and if I didn't know, then we could get flagged on an inspection. I know a guy who framed a full bath that was 35 sq/ft. Red flag! Had to install a pocket door to get the inspector to sign off....how do you feel about house wrap? Is it required? Insulation between the 2x's that you use for headers? Anchor bolts how far apart? Hurricane clips and strapping? See my point?
__________________
Ladwig Construction Hennessey, Oklahoma 405 853 1563 Ladwig Insulation & Construction Services Serving Oklahoma Statewide
|
|
|
|
|
|
#14 |
|
Pro
Trade: Remodeling
Join Date: Oct 2007
Location: Northwest Connecticut
Posts: 2,039
|
Re: 2*6 Studs The Norm?
Before we can build a house here you have to submit a mech-check.
It's a measure of all the components of your home that have to do with heating. It takes into consideration,insulation values,the U-Factors of all your windows as well as their sizes,furnace efficiency.sq.ft.of all exterior walls.ceiling heights,and doors. So using 2x6 framing will help exterior wall efficiency,although it's not code.Some guys frame 2x4 and add the 1" insulation to the exterior. As long as you pass the mech-check,your permit will be issued. |
|
|
|
|
|
#15 | |
|
Pro
Trade: Framing Contractor
Join Date: Jun 2004
Location: Caldwell, New Jersey
Posts: 1,541
|
Re: 2*6 Studs The Norm?Quote:
What is he telling them? What's the problem with adding a second story?
__________________
Joe Carola |
|
|
|
|
|
|
#16 |
|
Curmudgeon
Trade: carpentry/remodeling/"Yes M'am we do"
Join Date: Apr 2006
Location: Beech Grove, Indiana, Birthplace of the "King of Cool"
Posts: 11,707
|
Re: 2*6 Studs The Norm?
2X3's @24oc don't pass to support a second story here-a-bouts.
__________________
Put your location in your profile! (Sorry....it seems there really are dumb questions) |
|
|
|
|
|
#17 |
|
Pro
Trade: Carpentry / Fencing / Decks
Join Date: Oct 2007
Location: Savannah, Ga
Posts: 1,216
|
Re: 2*6 Studs The Norm?
2x4 here. I will step up to a 2x6 if I have wall height higher than 12'.. exterior only. I use 2x6 interior if I have pocket doors.
|
|
|
|
|
|
#18 |
|
Pro
Trade: Siding, Windows, Seamless Gutters, Metal Roofing
Join Date: Apr 2006
Posts: 2,761
|
Re: 2*6 Studs The Norm?
Joe, Im not a framer so I dont know if theres some other particulars besides just the 2x3's, but he insisted that as is,it would not have properly supported a second story.
|
|
|
|
|
|
#19 | |
|
Pro
Trade: Framing Contractor
Join Date: Jun 2004
Location: Caldwell, New Jersey
Posts: 1,541
|
Re: 2*6 Studs The Norm?Quote:
Sorry, I didn't see the part about 2x3's. Never seen 2x3 walls before except for basement framing. Other than that, second story addition go up all the time above 2x4 walls without any questions.
__________________
Joe Carola |
|
|
|
|
|
|
#20 |
|
Pro
Trade: Renovations
Join Date: May 2005
Location: West Coast Canada
Posts: 1,716
|
Re: 2*6 Studs The Norm?
2x6 is the norm here for insulative, not structural, reasons. 2x8 headers over windows depends on the load/span calcs and nothing else. Though the common thing is to use 2x10 for all load bearing, because it will handle it, and you don't need to have 2x8 kicking around the site that is useless for anything else.
2x6 for plumbing walls often; pocket doors here are usually 2x4; supply plumbing cannot be in an exterior wall(!) (apparently because it gets so cold here on the wet coast). Hose bibs must be buried in an interior wall partition so they are protected from the once yearly cold snap we get. Yeah, right.
__________________
From where does knowledge come? If you need to know what is in a box, you could ask someone (not reliable), you could pray, (not useful), you can consult with the scripture (not helpful) or you could open the box (science) |
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| cutting steel studs | 25BRIAN | General Discussion | 28 | 05-22-2009 09:41 AM |
| Steel Studs in Bulkhead | DSB_Const | Framing | 3 | 04-02-2009 03:12 PM |
| Fingerjointed Studs | Milhaus | Green Building | 20 | 05-18-2007 11:12 AM |
| Metal Studs Vs. Wood Studs | Towatei & Co. | Drywall | 7 | 05-12-2007 11:03 PM |
| Engineered studs? | RYANINMICHIGAN | Framing | 7 | 03-22-2006 05:28 PM |
| Go to Page... |