Photos For Another Use For Shingle Vent II As A Wall Vent
Here is a modification of the Shingle Vent II Ridge Vent we applied about 7 years ago, to be used as a top of a mansard wall vent to alleviate the severe 2nd story internal heat issues this home owner was suffering from.
Additionally, we applied a "Green" roofing system, ie; the white Duro-Last single ply membrane on the top flat roof surface. Notice in the photos, that we only painted the membrane which overlapped onto our newly created fascia board, which lent rigidity to the top of the Shingle Vent II Ridge Vent, which we cut in half for this installation. This was several years before I knew about the Smart Vent product manufactured by DCI Products, Inc. I now look back and feel that the Smart Vent would have been much better suited for this solution, but we made do with what we could think of. Now lets see if I learned how to resize and upload the photos. Ed |
|
|
|
|
|
#2 |
|
Pro
Trade: Roofing Contractor
Join Date: Dec 2006
Location: NW Suburbs of Chicago
Posts: 7,135
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
Only 3 photos at a time.
Ed |
|
|
|
|
|
#3 |
|
Pro
Trade: Roofing Contractor
Join Date: Dec 2006
Location: NW Suburbs of Chicago
Posts: 7,135
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
3 more.
Ed |
|
|
|
|
|
#4 |
|
Pro
Trade: Roofing Contractor
Join Date: Dec 2006
Location: NW Suburbs of Chicago
Posts: 7,135
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
Almost done. They did not wind up being in the right sequence. This is the last 3 photos guys.
Ed |
|
|
|
|
|
#5 |
|
Registered User
Trade: Roofing Contractor
Join Date: Oct 2007
Posts: 12
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
that looks good ed.
__________________
Never argue with an idiot, they'll drag you down to their level and beat you with experience. ~ Anonymous |
|
|
|
|
|
#6 |
|
Pro
Trade: Renovations
Join Date: May 2005
Location: West Coast Canada
Posts: 1,716
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
Nice detail, tks.
__________________
From where does knowledge come? If you need to know what is in a box, you could ask someone (not reliable), you could pray, (not useful), you can consult with the scripture (not helpful) or you could open the box (science) |
|
|
|
|
|
#7 |
|
Pro
Trade: Roofing Contractor
Join Date: Dec 2006
Location: NW Suburbs of Chicago
Posts: 7,135
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
If I run into this situation ever again, I would use the Smart Vent from DCI Products and adapt that to the top of the wall, instead of cutting the Shingle Vent II in half like I did here.
Ed |
|
|
|
|
|
#8 |
|
Thom
Trade: General Contractor/Homebuilder
Join Date: Nov 2006
Location: Albuquerque NM
Posts: 3,197
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
Ed, your work looks fine but, that's one funky looking house.
|
|
|
|
|
|
#9 |
|
Al Smith
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
Cor a vent makes strip vents for situations like that. I used to use their ridge vent years ago when it seemed to be popular in fine homebuilding. It got to be ridiculously expensive though at 12 dollars for a four foot section so I stopped using it and started using the more popular and less expensive cobra ridge vent.
Last edited by A W Smith; 11-01-2007 at 12:45 PM. |
|
|
|
|
|
#10 |
|
Sharpie
Trade: Renovation contractor
Join Date: Jan 2008
Location: Mission B.C.
Posts: 224
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
Looks like an old Pizza Hut to me.
__________________
Travis www.customkreations.ca "The most perfect technique is that which is not noticed at all" -Pablo Casals |
|
|
|
|
|
#11 |
|
Pro
Trade: Roofing Contractor
Join Date: Dec 2006
Location: NW Suburbs of Chicago
Posts: 7,135
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
I don't design the houses people live in, I just roof them and ventilate them to the best available knowledge I have gained over the years, and when a predicament with no quick easy answer rears its ugly head, I try to do the adapt those priciples the best that I can.
Ed |
|
|
|
|
|
#12 |
|
Pro
Trade: GC/Remodeling
Join Date: Sep 2007
Location: Central America (Kansas)
Posts: 1,925
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
Nice touch...looks like it was made for that app.
__________________
-Steve "The most beautiful thing we can experience is the mysterious. It is the source of all true art and science." ~ Albert Einstein |
|
|
|
|
|
#13 |
|
Pro
Trade: Roofer, Domains and Hosting
Join Date: Nov 2004
Location: Richmond, Va.
Posts: 2,456
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
I remember these pics. Nice job.
__________________
Frank Slate Roof Repairs, Richmond, Va. |
|
|
|
|
|
#14 |
|
3rd gen,it's in the blood
Trade: roofing
Join Date: Oct 2006
Location: Roellen,TN
Posts: 458
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
what was the flat roof painted with?
__________________
You have ONE advantage over me.....you can kiss my butt and I can't!! |
|
|
|
|
|
#15 |
|
Pro
Trade: Roofing Contractor
Join Date: Dec 2006
Location: NW Suburbs of Chicago
Posts: 7,135
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
I only painted the apron that hung down over the fascia and the chimney flashing material.
I forget exactly what I used. That was about 7 years ago and is still clinging on as good today as when it was first installed. I probably used a Rustoleum or Ace Hardware version of the same though. Those are my most common, but the HO may have given me some from her stock to match colors. Ed |
|
|
|
|
|
#16 |
|
3rd gen,it's in the blood
Trade: roofing
Join Date: Oct 2006
Location: Roellen,TN
Posts: 458
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
ever painted epdm?
__________________
You have ONE advantage over me.....you can kiss my butt and I can't!! |
|
|
|
|
|
#17 |
|
Pro
Trade: Roofing Contractor
Join Date: Dec 2006
Location: NW Suburbs of Chicago
Posts: 7,135
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
No, never had the need to.
I don't touch EPDM since I started my own company 24 + years ago and for the 8 years before that in the union, it was never done. Ed |
|
|
|
|
|
#18 |
|
3rd gen,it's in the blood
Trade: roofing
Join Date: Oct 2006
Location: Roellen,TN
Posts: 458
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
I run into the situation from time to time and was curious if you had,and how you handled it.
__________________
You have ONE advantage over me.....you can kiss my butt and I can't!! |
|
|
|
|
|
#19 |
|
Pro
Trade: Residential roofing
Join Date: Apr 2008
Location: Colorado
Posts: 102
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
Nice job Ed, I use the SVII in a few different applications also, and prefer it for the higher air flow you get than from the DCI product. The vent going all around like that was an excellent idea.
|
|
|
|
|
|
#20 |
|
Pro
Trade: Roofing Contractor
Join Date: Dec 2006
Location: NW Suburbs of Chicago
Posts: 7,135
|
Re: Photos For Another Use For Shingle Vent II As A Wall Vent
It used to be a sweat box on that upper floor of these two elderly womens home.
I have to check back again this summer, but right after I did that job, they said it was much more comfortable. They used to have to run their A/C 100% full time. I also have to give credit to the White Duro-Last roof membrane on the top flat roof. That cools off the surface dramatically, so it is not all due to the ventilation solution I installed. Ed
__________________
Please Stay Tuned For A Very Important Message From Our Sponsor http://www.rightwayroofingcompany.com/ www.rightwayroofingcompany.com Roof Estimates, Roof Repairs, Roofers, Roof Leak Help, Elgin, Carpentersville, East Dundee, West Dundee, Sleepy Hollow, Algonquin, South Elgin, Huntley, Lake In The Hills, Illinois |
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Load bearing wall or not??? | BMAN | Remodeling | 26 | 07-28-2008 07:16 PM |
| Another Use For Shingle Vent II As A Wall Vent | Ed the Roofer | Roofing | 7 | 08-06-2007 10:34 AM |
| Backyard office, retaining, and privacy wall | Team Scream | Masonry | 8 | 08-02-2007 11:27 PM |
| moving centennial wall | stacker | Masonry | 4 | 10-20-2006 12:12 AM |
| Low (12" or so) brick garden wall questions | bindersbee | Masonry | 8 | 04-27-2006 08:31 PM |
| Go to Page... |