Ventilation Concerns


I'll be building a single story 14' X 14' 'shed-roof' addition off the back wall of a 1 1/2-story (dormered) home. Can't gable the roof because of 2nd floor windows. Roof will only be 3 in 12, with dimensional shingles, and total coverage of ice/water-shield. Can't increase pitch either. Rafters will be 2 X 8's. Ceiling will be vaulted.

What's the best way to 'ventilate' this roof??

Bottom end can be vented soffit, - - not a problem. Insulation w/baffles, - - fine.

How about at the top, - - where the roof meets the wall??

Seems like venting up top would possible create a future water problem because of the mimimal pitch. I'd prefer to vent the bottom only in this situation, but the 'powers that be' want it vented.

Anyone run into this??
Tom R is offline  

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

   

Advertisement

 

Old 08-27-2005, 02:35 AM   #2
Pro
 
reveivl's Avatar
 
Trade: Renovations
Join Date: May 2005
Location: West Coast Canada
Posts: 1,716
Rewards Points: 1,000

Re: Ventilation Concerns


Use 2x10 rafters and cut them down at the top to 2x8 for the last 12" or so (cut a wedge off), (or nail a 2x2 on), support the edge of the ply with a ledger against the building and use low-slope (gooseneck) vents. The wedges cut out provide cross ventilation. That passed for me once. Rich.

Advertisement

__________________
From where does knowledge come? If you need to know what is in a box, you could ask someone (not reliable), you could pray, (not useful), you can consult with the scripture (not helpful) or you could open the box (science)
reveivl is offline  
Old 08-27-2005, 08:20 AM   #3
Pro
 
Tom R's Avatar
 
Trade: Carpenter
Join Date: May 2004
Posts: 6,858
Rewards Points: 2,036

Re: Ventilation Concerns


Quote:
Originally Posted by reveivl
Use 2x10 rafters and cut them down at the top to 2x8 for the last 12" or so (cut a wedge off), (or nail a 2x2 on), support the edge of the ply with a ledger against the building and use low-slope (gooseneck) vents. The wedges cut out provide cross ventilation. That passed for me once. Rich.
Eric,

Brilliant!! Thanks. That's the ticket. You've Reveivl'd my faith!!
Tom R is offline  
   
 
Old 08-27-2005, 09:52 AM   #4
Pro
 
reveivl's Avatar
 
Trade: Renovations
Join Date: May 2005
Location: West Coast Canada
Posts: 1,716
Rewards Points: 1,000

Re: Ventilation Concerns


Eric????
__________________
From where does knowledge come? If you need to know what is in a box, you could ask someone (not reliable), you could pray, (not useful), you can consult with the scripture (not helpful) or you could open the box (science)
reveivl is offline  
Old 08-27-2005, 12:57 PM   #5
Registered User
 
Grumpy's Avatar
 
Trade: Roofing and Gutter Specialist
Join Date: Oct 2003
Location: Chicago
Posts: 8,573
Rewards Points: 2,000

Re: Ventilation Concerns


I'd do soffit vents in combination with some one way breather vents on the shed roof... or if I am invisioning this correctly I would just cut holes in the existing roof deck where the new roof meets the old... Or is this new roof joining a wall?

If it's impossible to vent this roof into an existing vented space, then just install the one way breather vents, sometimes called bullets. Ugly but effective.
__________________
-Grumpy
Chicago Gutters Chicago Roofing
Grumpy is offline  
Old 08-27-2005, 04:15 PM   #6
Pro
 
Tom R's Avatar
 
Trade: Carpenter
Join Date: May 2004
Posts: 6,858
Rewards Points: 2,036

Re: Ventilation Concerns


Quote:
Originally Posted by reveivl
Eric????
Sorry Rich, - - don't know where I got that.

I guess too much skippin around the posts.

I better stick to reveivl!!

How about, - - Sorry, Thanks!! :Thumbs:
Tom R is offline  
Old 08-27-2005, 04:18 PM   #7
Pro
 
Tom R's Avatar
 
Trade: Carpenter
Join Date: May 2004
Posts: 6,858
Rewards Points: 2,036

Re: Ventilation Concerns


Quote:
Originally Posted by Grumpy
I'd do soffit vents in combination with some one way breather vents on the shed roof... or if I am invisioning this correctly I would just cut holes in the existing roof deck where the new roof meets the old... Or is this new roof joining a wall?

If it's impossible to vent this roof into an existing vented space, then just install the one way breather vents, sometimes called bullets. Ugly but effective.
Yeah, Grump, - - it's a roof-meets-wall.

Not familiar with so-called 'bullets'.
Tom R is offline  
Old 08-28-2005, 08:21 PM   #8
Pro
 
red_cedar's Avatar
 
Join Date: Mar 2005
Posts: 1,000
Rewards Points: 1,250

Re: Ventilation Concerns


If you cut a continuous slot of apx. 1 -1.5 inches or so along the top where the roof meets the wall. Cut and lay a material that is the same as what one uses for the ridge vent detail, lay your roof to wall flashing over the venting piece. There are various attachment options for this. 3/ 12 pitch shouldnt be a problem. I have used this detail succesfully in various situations from the one described to the top (Ridge) of a shed roof. I prefer the cobra venting.
red_cedar is offline  
Old 08-29-2005, 03:09 PM   #9
Registered User
 
Grumpy's Avatar
 
Trade: Roofing and Gutter Specialist
Join Date: Oct 2003
Location: Chicago
Posts: 8,573
Rewards Points: 2,000

Re: Ventilation Concerns


BTW they do manufacture roof-to-wall vents very similiar to what cedar just described, I've never used 'em though.
__________________
-Grumpy
Chicago Gutters Chicago Roofing
Grumpy is offline  
Old 08-29-2005, 03:11 PM   #10
Registered User
 
Grumpy's Avatar
 
Trade: Roofing and Gutter Specialist
Join Date: Oct 2003
Location: Chicago
Posts: 8,573
Rewards Points: 2,000

Re: Ventilation Concerns


http://www.klober.co.uk/printer-friendly.php?id=95 for the flat roof vents
__________________
-Grumpy
Chicago Gutters Chicago Roofing
Grumpy is offline  
Old 09-06-2005, 08:42 PM   #11
Pro
 
TimNJ's Avatar
 
Trade: Remodeler
Join Date: Sep 2005
Posts: 5,319
Rewards Points: 2,970

Re: Ventilation Concerns


TomR, Call Diamond M. They sell prefab metal roof to wall vents. I have bought them from them. PS. Newbie here and right in your area of NJ Tom.
TimNJ is offline  
Old 09-06-2005, 09:41 PM   #12
Pro
 
Tom R's Avatar
 
Trade: Carpenter
Join Date: May 2004
Posts: 6,858
Rewards Points: 2,036

Re: Ventilation Concerns


Quote:
Originally Posted by TimNJ
TomR, Call Diamond M. They sell prefab metal roof to wall vents. I have bought them from them. PS. Newbie here and right in your area of NJ Tom.
Thanks, Tim, - - yeah, maybe if I get a chance, I'll run down there Saturday morning and at least check 'em out, - - where are you located at?? In business for yourself?? What all kind of work??
Tom R is offline  
Old 09-07-2005, 08:38 PM   #13
Pro
 
TimNJ's Avatar
 
Trade: Remodeler
Join Date: Sep 2005
Posts: 5,319
Rewards Points: 2,970

Re: Ventilation Concerns


Tom, I am in Jacobstown right down 528. I started in the field at 17 and went into business at 25 (1983).
TimNJ is offline  
Old 09-07-2005, 09:02 PM   #14
Pro
 
Tom R's Avatar
 
Trade: Carpenter
Join Date: May 2004
Posts: 6,858
Rewards Points: 2,036

Re: Ventilation Concerns


Oh OK, - - I did a big deck over that-a-way a few years back, - - 2 levels, - - 3 staircases, - - an' all that, - - I forget now, - - maybe it was Arneytown Road??, - - anyway, - - it was 'North Hanover', - - somewhere near a military graveyard.

I live right on Rt 206 in N. Bordentown, - - almost in Hamilton.

I do most of my work in Bordentown, Hamilton, Lawrenceville area.

Be talkin' to ya'!!

Advertisement

Tom R is offline  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Ventilation and Shingle Tests Online Ed the Roofer Roofing 10 01-09-2008 08:18 AM
Debating Attic Ventilation Pros and Cons Ed the Roofer Roofing 14 08-22-2007 02:21 PM
Do I still need to calculate ventilation? nolo Roofing 10 08-11-2007 11:02 AM
Health Concerns I Just Found Out About Ed the Roofer General Discussion 39 07-29-2007 04:19 PM
Ventilation techniques darcar Construction 5 11-28-2006 03:32 PM

Join Now... It's Fast and FREE!

I am a professional contractor
I am a DIY Homeowner
Drywall Talk is for
PROFESSIONAL CONTRACTORS ONLY!

At DrywallTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?