Re: Standing Seam Metal Over 3-tab??
do what you want,I've seen people with the mysterious leaks that only happen on hot days and their a/c blasting.ever grab a soda out of the fridge on a hot summer day?where do you think the water goes on a metal roof?
it may not be as drastic but it does happen
__________________
You have ONE advantage over me.....you can kiss my butt and I can't!! |
|
|
|
|
|
#22 |
|
Pro
Trade: Residential General
Join Date: Mar 2007
Posts: 398
|
Re: Standing Seam Metal Over 3-tab??
I don't think you understand condensation and moisture migration through homes very well roofwiz.
|
|
|
|
|
|
#23 |
|
Member
Trade: roofing
Join Date: Mar 2006
Posts: 46
|
Re: Standing Seam Metal Over 3-tab??
If you remove the Asphalt roof. Can you attach the underlayment and the Metal (Standing Seam) directly to the plywood?
|
|
|
|
|
|
#24 |
|
3rd gen,it's in the blood
Trade: roofing
Join Date: Oct 2006
Location: Roellen,TN
Posts: 458
|
Re: Standing Seam Metal Over 3-tab??
I try,I have more exp. in repairing the systems that have failed.I have a good basic understanding of venting of roofs and going over old.more so in commercial projects.As far as complete home venting,moisture,blah..no.Just the basics as far as the complete home system.
Been on hundreds of metal roofs on homes,barns,factories,schools you name it.I've seen lots of things go wrong. from what I understand he want to put a metal roof right over the top of a three tab asphalt shingle roof. as far as my thinking goes.. the metal will look like crap on top of shingles.The granules will rub the paint off and cause it to rust. and I think that if he lives in a place like some that I have , where there are drastic changes in temp frequently.and I have seen condesation on both sides of a metal roof.the water may make a small mystery leak. I don't know his house,venting ,bathing and cooking habits or anything.just something to think about. seems to make sense in my head somehow.
__________________
You have ONE advantage over me.....you can kiss my butt and I can't!! Last edited by roofwiz74; 03-27-2007 at 06:11 PM. |
|
|
|
|
|
#25 |
|
3rd gen,it's in the blood
Trade: roofing
Join Date: Oct 2006
Location: Roellen,TN
Posts: 458
|
Re: Standing Seam Metal Over 3-tab??
use the right underlayment.and have fun beating in nails.
I like to pull them and renail the wood where ever it needs it.
__________________
You have ONE advantage over me.....you can kiss my butt and I can't!! |
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| chimney flashing on standing seam roof | kermmonk | Construction | 22 | 02-19-2010 03:39 PM |
| metal cold roof question ..... | Vermonster | Roofing | 30 | 09-06-2007 01:30 AM |
| Standing Seam Rate around Greensboro NC | TurnkeyConst | Roofing | 9 | 04-04-2007 07:17 PM |
| Standing seam metal roof? | kermmonk | Roofing | 1 | 08-14-2006 10:34 PM |
| Go to Page... |