Spot On Roof
I was waiting for a builder one day and noticed this on the house next door. I have seen this occasionally on some houses and wonder what causes it?
__________________
If you correct your mind, the rest of your life will fall into place ~Lao Tzu Custom Cabinetry - Portland, Cape Elizabeth, Scarborough, Kennebunkport, Yarmouth, Falmouth, Cumberland, Ogunquit, Maine Salmon Falls Cabinetry |
|
|
|
|
|
#2 |
|
KemoSabe
Trade: residential framing/siding/general carpentry
Join Date: Feb 2009
Location: Vineland, New Jersey
Posts: 12,817
|
Re: Spot On Roof
Possibly a venting issue with the rafters in the sloped ceiling?
__________________
__________________________________ "Walking the fine line between production and perfection" __________________________________ |
|
|
|
|
|
#3 | |
|
Pro
Trade: Thoroughbred Roofer
Join Date: Apr 2006
Posts: 3,119
|
Re: Spot On RoofQuote:
Excessive condensation build up? Bad sheet of plywood that's delaminating? My first impression was that they tarred the roof in that area to stop some sort of leak. Or, a particular area where snow builds up and rots the shingles from sitting there (again, another area where there might be hot air escaping through the deck especially at a point where valley rafters meet). Ultimately, if I had to guess from the pic (which is extremely difficult to do), I'd say it was faulty decking that's contributing to the shingles premature failure.
__________________
"I've been up on the roof. I know what those guys go through. My whole life has been about making that profession respectable." Ken Hendricks www.SolutionsRoofing.com |
|
|
|
|
|
|
#4 |
|
Roofer
Trade: Residential Contractor
Join Date: Dec 2007
Location: Struthers Ohio 44471
Posts: 681
|
Re: Spot On Roof
I would say it's a ventilation issue, if they blocked off access to the main roof cavity with the raised ceiling over that round top window.
Could also be an insulation issue tho, if they did not properly insulate that ceiling area it could be staying cooler longer in that area. Maybe a combination of both.
__________________
|
|
|
|
![]() |
| Thread Tools | Search this Thread |
| Display Modes | Rate This Thread |
|
|
Similar Threads
|
||||
| Thread | Thread Starter | Forum | Replies | Last Post |
| Ballast Removal from EPDM Roof? | tekwrytr | Roofing | 26 | 06-19-2009 05:12 PM |
| rubber roof over rolled asphalt ? ? | btownpa | Roofing | 2 | 03-06-2009 03:03 PM |
| Tying into existing roof | Milhaus | Framing | 9 | 11-06-2008 12:03 PM |
| Ice Problems on a roof | J-Peffer | Roofing | 4 | 10-01-2008 11:12 AM |
| Go to Page... |