Old 09-09-2009, 08:25 PM   #1
Pro
Trade: renovator
 
Join Date: Jan 2008
Posts: 330
Flat roof re-roof debate

Gentlemen,

I'm not doing this one myself, outta my league - but I'd love your opinions on what's the best thing to have someone else do.

Dead flat roof on a century old Victorian. I haven't been up on it yet to know what it's currently covered with, but it's leaking - bad. Commercial guys will assure me that a properly done flat roof is bullet proof, stop whining. Call me a wuss, I figure gravity's about the most reliable thing on the planet. I want a slope.

EPDM on wedged insulation?

Standing seam steel on a new deck on wedged sleepers?

Or suck it up and torch or hot mop back onto the flat?

What is the apex of current technology for this?

Thanks.

bob_cntrctr is offline   Reply With Quote
Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

Join Contractor Talk

Join the #1 Contractor Forum Today - It's Totally Free!

ContractorTalk.com - Are you a Professional Contractor? If so we invite you to join our community and see what it has to offer. Our site is specifically designed for you and it's the leading place for contractors to meet online. No homeowners asking DIY questions. Just fellow tradesmen who enjoy talking about their business, their trade, and anything else that comes up. No matter what your trade is you'll find that ContractorTalk.com is a great community to join. Best of all it's totally free!

Join ContractorTalk.com - Click Here JOIN FOR FREE

Old 09-10-2009, 05:38 AM   #2
Roofer
 
Slyfox's Avatar
Trade: Residential Roofing
 
Join Date: Dec 2007
Location: Struthers Ohio 44471
Posts: 426
The more slope there is the longer the system will last.

Metal properly installed on even low slope situations will last longer than any of the other systems you mentioned.

BTW, I'm a hot maggot, I have installed many a 4 ply dead asphalt, pitch and torch downs and you can easily get 20 years out of those systems with minor maintenance.
That don't change the fact the metal on a slope will last longer.
__________________
God Fearing, Husband/Father, US American, Pool Shooting Roofer
Slyfox is offline   Reply With Quote
Old 09-10-2009, 06:01 AM   #3
Pro
Trade: Remodeling
 
Join Date: Mar 2007
Location: Northeast, Pa
Posts: 945
duro-last roofing. I have seen it 20 years and hold standing water. I don't put it down, but have another contractor that does
__________________
'The trouble with our liberal friends is not that they're ignorant; it's just that they know so much that isn't so.' - Ronald Reagan
PA woodbutcher is offline   Reply With Quote
Old 09-10-2009, 08:25 AM   #4
Pro
Trade: Siding, Metal Roofs, and whatever to pay the bills
 
Join Date: Jul 2008
Location: Eastern NM / West Tx
Posts: 116
Im with sly pitch it and metal.


You can get many different styles besides standing seam or R.
With tax rebate and lower insurance there are alot of flat roofs getting pitched here
Red Adobe is offline   Reply With Quote
Old 09-12-2009, 09:56 PM   #5
Commercial Roofing
 
AaronB.'s Avatar
Trade: Roofing Contractor
 
Join Date: Oct 2004
Location: Lockport, IL
Posts: 1,103
You could apply a seamless vapor barrier system unaffected by water like polyurea. On dead flat, if you went with metal, I would say you would havr to go with flat locked and soldered seams.

I still wouldn't put on a 4 ply asphalt with even a FR MB cap sheet cuz asphaltic products are all breathers.
__________________
Picking up the slack
www.roseroofing.net
Metal Roof Rehabilitation, Commercial Roofing, Polyurea Roofing Systems, Commercial Spray Foam, Leak Detection and Repair
AaronB. is offline   Reply With Quote
Old 09-13-2009, 05:26 PM   #6
Member
Trade: Roofing Contractor
 
Join Date: May 2009
Location: NW, OH
Posts: 66
Duro-Last I been doing it for 5 years and never had a roof fail. I have seen it twenty years old just l like Wood Butcher said and it still don't leek. It dont have to have a slope.
__________________
\
Gilby is offline   Reply With Quote
Old 09-13-2009, 09:16 PM   #7
Registered User
Trade: Roofing, siding, windows, remodeling
 
Join Date: Sep 2009
Posts: 1
This is an easy project, but could be tricky. Metal would be great, but you still need a pitch to it. Since its level now, the best you can hope for is 1/4" per foot (with tapered insulation). This, as previously stated, will require flat lock seams that are fully soldered. This can get quite expensive and also requires maintenance (painting) if its not done in copper.

Durolast, a PVC product, would do fine but is more expensive than other PVC membranes as they custom make the roof and flashings. They also include the warranty fee in the cost of the material, which may not be necessary since this is residential. (Durolast does not give full warranties on small residential properties as so many other manufacturers of flat roofing products).

I believe that PVC would be the best product in this case. My choice would be IB roof systems as they provide a lifetime warranty for residential roofing properties. My second choice would be fibertite. Fibertite does not offer the same warranty, but their product is one of the more superior PVC products on the market as they use Elvaloy in the formulation.

You can research both of these products on their websites. In the end, IB would be the best option (in my opinion). By the way, I have been installing flat roofing systems for over 20 years on residential properties in the Washington DC area.

Good luck. If I can answer any questions or be of any help, I would be happy to do so. I am new to this forum.
Scott Siegal is offline   Reply With Quote
Old 09-14-2009, 09:01 AM   #8
Pro
Trade: renovator
 
Join Date: Jan 2008
Posts: 330
Appreciate all the answers so far - just so everyone knows I'm still reading. I'll be researching the various membrane systems mentioned.

As for pitch and tapered insulation - I think I'd be more likely to tear off the old deck (most likely 1" x 12" barn board) and frame a 1/4" to 1/2" pitch to it, building onto the existing - at which point I could either way, membrane of metal.
bob_cntrctr is offline   Reply With Quote
Old 09-14-2009, 09:28 PM   #9
Member
Trade: Roofing
 
Join Date: Nov 2004
Posts: 84
Quote:
What is the apex of current technology for this?
A flat lock soldered seam copper roof.

dennis is offline   Reply With Quote
Old 09-14-2009, 11:13 PM   #10
Commercial Roofing
 
AaronB.'s Avatar
Trade: Roofing Contractor
 
Join Date: Oct 2004
Location: Lockport, IL
Posts: 1,103
80 mil seamless polyurea. Simple.
__________________
Picking up the slack
www.roseroofing.net
Metal Roof Rehabilitation, Commercial Roofing, Polyurea Roofing Systems, Commercial Spray Foam, Leak Detection and Repair
AaronB. is offline   Reply With Quote
Old 09-21-2009, 11:58 PM   #11
Registered User
Trade: Roofng
 
Join Date: Jul 2007
Posts: 7
Single-ply with slope

Tear-off all roofing materials to wood deck, and install 1/4" tapered Polyisocyanurate insulation. Fasten to deck with 5 screws and plates per 4' x4' board.

Adher and 60-mil EPDM Rubber or 60-Mill PVC, (TPO?) to insulation with bonding adhesive. Use new lumber at details, and properly flash all edges. The workmanship of the perimeter will determine the quality of the roof. Hold back your final 20% payment untill a few thunderstorms have tested the roof.
theflynner is offline   Reply With Quote
Old 09-22-2009, 07:12 AM   #12
stop botherin' me!
 
Grumpy's Avatar
Trade: Roofing Siding Gutters Windows
 
Join Date: Oct 2003
Location: Chicago
Posts: 7,505
Send a message via AIM to Grumpy
Slope it no less than 1/8" per foot, preferrably 1/4", with tapered insulation. Your choice of membrane. I prefer white theromplastic single ply such as TPO or PVC.

Metal is fine if it's flat locked at the low slope. It it's steep sloped (3/12+) then standing seam willbe ok. I'd be afraid to do standing seam less than 3/12. Metal will most likely cost signifigantly more than a low slope membrane.
__________________
-Grumpy
Chicago Gutters Chicago Roofing
Grumpy is offline   Reply With Quote
Reply


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Flat Roof repairs BattleRidge Roofing 11 03-24-2009 09:34 AM
rubber roof over rolled asphalt ? ? btownpa Roofing 2 03-06-2009 03:03 PM
2 storey deck on top of flat roof woodworkbykirk Decks & Fencing 5 10-27-2008 08:59 AM