Building Collapse In Geneva


http://spectrumlocalnews.com/nys/roc...hip-lyons-road

About 10 miles from where we were working today, a cold front came through early afternoon with some crazy wind gusts, our siding was blowing all over the place for a little while.
mrcat is online now  

Warning: The topics covered on this site include activities in which there exists the potential for serious injury or death. ContractorTalk.com DOES NOT guarantee the accuracy or completeness of any information contained on this site. Always use proper safety precaution and reference reliable outside sources before attempting any construction or remodeling task!

   

Advertisement

 

Old 01-23-2018, 08:46 PM   #2
Pro
 
mrcat's Avatar
 
Trade: Pole Barns, Residential Framing
Join Date: Jun 2015
Location: Fingerlakes NY
Posts: 188
Rewards Points: 132

Re: Building Collapse In Geneva


http://www.fingerlakesdailynews.com/...ted-in-geneva/

Here's some better pictures, can't tell if they had all the walls sheeted or not. I'll probably find out more tomorrow, the GC we're framing for is a building inspector for a nearby town, he'll probably know more about it.

Advertisement

mrcat is online now  
Old 01-23-2018, 09:10 PM   #3
Pro
 
kirkdc's Avatar
 
Trade: Remodeling (mostly kitch/bath)
Join Date: Feb 2017
Location: Cripple Creek. CO
Posts: 648
Rewards Points: 2,734

Re: Building Collapse In Geneva


wow ! I'm glad no one was hurt. It didnt seem that windy there. ???
kirkdc is offline  
   
 
Old 01-24-2018, 08:08 AM   #4
Pro
 
B.Johnson's Avatar
 
Trade: Builder
Join Date: Sep 2016
Location: Midwest
Posts: 701
Rewards Points: 658

Re: Building Collapse In Geneva


Quote:
Originally Posted by mrcat View Post
http://www.fingerlakesdailynews.com/...ted-in-geneva/

Here's some better pictures, can't tell if they had all the walls sheeted or not. I'll probably find out more tomorrow, the GC we're framing for is a building inspector for a nearby town, he'll probably know more about it.
That's what I was wondering, my guess would be that they weren't sheeted.
__________________
Home Designer Series Software
B.Johnson is offline  
Old 01-24-2018, 08:27 AM   #5
General Contractor
 
greg24k's Avatar
 
Trade: New Home Construction-Additions-Remodeling
Join Date: May 2007
Location: NJ
Posts: 7,055
Rewards Points: 7,088

Re: Building Collapse In Geneva


Matchbox structures... What you expect. Glad nobody got hurt.
__________________
I never lost a cent on the jobs I didn't get!
greg24k is offline  
Old 01-24-2018, 09:25 AM   #6
Pro
 
hdavis's Avatar
 
Trade: remodeling
Join Date: Feb 2012
Location: CoastalME
Posts: 19,227
Rewards Points: 4,629

Re: Building Collapse In Geneva


When you get a building sheeted with some significant openings, a wind gust can blow in through the openings, and if it has nowhere to go, it can lift the roof system. On a simple rectangular building, once the top plate becomes detached (gable ends have the greatest shear force on the plate), those walls blow out, and the building blows over.

It's a big risk on some designs once walls are mostly sheeted.

Maybe what happened here.
hdavis is online now  
The Following 2 Users Say Thank You to hdavis For This Useful Post:
Fouthgeneration (01-24-2018), mrcat (01-24-2018)
Old 01-24-2018, 10:44 AM   #7
Pro
 
mrcat's Avatar
 
Trade: Pole Barns, Residential Framing
Join Date: Jun 2015
Location: Fingerlakes NY
Posts: 188
Rewards Points: 132

Re: Building Collapse In Geneva


Quote:
Originally Posted by hdavis View Post
When you get a building sheeted with some significant openings, a wind gust can blow in through the openings, and if it has nowhere to go, it can lift the roof system. On a simple rectangular building, once the top plate becomes detached (gable ends have the greatest shear force on the plate), those walls blow out, and the building blows over.

It's a big risk on some designs once walls are mostly sheeted.

Maybe what happened here.
I bet this is what happened, the gc we're working for now, said he drove by there a few days ago, and it looked like they had everything sheeted, but one whole side was full of overhead door openings.

Needless to say, he's really preaching bracing to us this morning. Which is just fine with me, I hope I never have one go down like that...

Sent from my SM-G900V using Tapatalk
mrcat is online now  
The Following User Says Thank You to mrcat For This Useful Post:
hdavis (01-24-2018)
Old 01-24-2018, 05:51 PM   #8
Pro
 
hdavis's Avatar
 
Trade: remodeling
Join Date: Feb 2012
Location: CoastalME
Posts: 19,227
Rewards Points: 4,629

Re: Building Collapse In Geneva


Bracing isn't always enough if the roof lifts.
hdavis is online now  
Old 01-24-2018, 06:39 PM   #9
Pro
 
Fouthgeneration's Avatar
 
Trade: Masonry
Join Date: Jan 2014
Location: Mid west
Posts: 1,590
Rewards Points: 5,641

Re: Building Collapse In Geneva


Tarp the openings, or leave some sheathing off for wind flow.... Hinged plywood Flaps for the over achievers.
Maybe some Tornado ties......

OSHA says over 28 mph winds get down out of man lifts without Pro opinion to the contrary.

35 mph for old school pipe scaffold.....tied off to regulations.

Some insurance company just took a loss.... and our rates rise some more...

Blown over by a 45 or 50 mph gust is just gross incompetence, and appears to be a little undermanned, 2 men for 10,000 square feet ?
__________________
I might be an Idiot, but I know things that You don't: Please wait till after you get my know-how to insult me....

Last edited by Fouthgeneration; 01-24-2018 at 07:07 PM.
Fouthgeneration is offline  
Old 01-24-2018, 07:17 PM   #10
Pro
 
hdavis's Avatar
 
Trade: remodeling
Join Date: Feb 2012
Location: CoastalME
Posts: 19,227
Rewards Points: 4,629

Re: Building Collapse In Geneva


This isn't gross incompetence.
hdavis is online now  
The Following User Says Thank You to hdavis For This Useful Post:
mrcat (01-24-2018)
Old 01-24-2018, 07:48 PM   #11
Pro
 
Framer53's Avatar
 
Trade: Handyman
Join Date: Feb 2008
Location: Utica,NY
Posts: 2,952
Rewards Points: 254

Re: Building Collapse In Geneva


I have a suspicion they bracing was not sufficient.
Framed several that size and used cubes of 16'ers for bracing until the windows were in.
Framer53 is offline  
Old 01-24-2018, 08:15 PM   #12
Pro
 
mrcat's Avatar
 
Trade: Pole Barns, Residential Framing
Join Date: Jun 2015
Location: Fingerlakes NY
Posts: 188
Rewards Points: 132

Re: Building Collapse In Geneva


Quote:
Originally Posted by Fouthgeneration View Post

Blown over by a 45 or 50 mph gust is just gross incompetence, and appears to be a little undermanned, 2 men for 10,000 square feet ?
There were 5 workers on site, just the 2 that were injured.
The owner of the company was one of the injured, apparently he's in guarded condition as of this morning.



Sent from my SM-G900V using Tapatalk
mrcat is online now  
The Following User Says Thank You to mrcat For This Useful Post:
hdavis (01-24-2018)
Old 01-24-2018, 08:31 PM   #13
Business Owner
 
P42003's Avatar
 
Trade: Pest & Termite Control
Join Date: Jun 2016
Location: Paducah, KY (far West Kentucky)
Posts: 253
Rewards Points: 6

Re: Building Collapse In Geneva


On Facebook, a "Spencer Tulis", photographer for Finger Lakes Times, has a couple more pictures on his personal page.
P42003 is online now  
The Following User Says Thank You to P42003 For This Useful Post:
hdavis (01-24-2018)
Old 01-24-2018, 08:40 PM   #14
Pro
 
mrcat's Avatar
 
Trade: Pole Barns, Residential Framing
Join Date: Jun 2015
Location: Fingerlakes NY
Posts: 188
Rewards Points: 132

Re: Building Collapse In Geneva


Quote:
Originally Posted by hdavis View Post
This isn't gross incompetence.
I don't think it is either, it's not a fly by night company, I think they've been around for 30 some years.
I'll be interested to hear what they determine failed.

Sent from my SM-G900V using Tapatalk
mrcat is online now  
The Following User Says Thank You to mrcat For This Useful Post:
hdavis (01-24-2018)
Old 01-24-2018, 08:59 PM   #15
Pro
 
hdavis's Avatar
 
Trade: remodeling
Join Date: Feb 2012
Location: CoastalME
Posts: 19,227
Rewards Points: 4,629

Re: Building Collapse In Geneva


We had a school(?) under construction collapse at that stage of construction under similar circumstances. I don't think you see this happen in hurricane country due to the required ties.
hdavis is online now  
The Following User Says Thank You to hdavis For This Useful Post:
mrcat (01-24-2018)
Old 01-25-2018, 10:08 PM   #16
Pro
 
Fouthgeneration's Avatar
 
Trade: Masonry
Join Date: Jan 2014
Location: Mid west
Posts: 1,590
Rewards Points: 5,641

Re: Building Collapse In Geneva


Engineering wise, one usually figures that the partial building during construction should survive the greatest average wind in a 6 month period.... usually in the 70-85 mph range here in the MidWest, Longer jobs get a 5 or 10 mph added to temporary design wind loads... high value and high priority jobs might get special attention....

A failure at ~45mph is not going to please any underwriters.

WAG: the roof formed an air foil and achieved "take off velocity..."

No one can build profitably and eliminate all weather risks... This one I guess is on the Engineers or lack there of.... The wind gusts were un-usual, but not freakish....

One small benefit of the Wind Mill silliness is there is much better REAL TIME wind data across the USA....

And the InterNet weather had wind gust warnings..... Up to 70 Mph?
__________________
I might be an Idiot, but I know things that You don't: Please wait till after you get my know-how to insult me....

Last edited by Fouthgeneration; 01-25-2018 at 10:20 PM.
Fouthgeneration is offline  
Old 01-26-2018, 12:27 AM   #17
Pro
 
hdavis's Avatar
 
Trade: remodeling
Join Date: Feb 2012
Location: CoastalME
Posts: 19,227
Rewards Points: 4,629

Re: Building Collapse In Geneva


This probably isn't just simple uplift.

Advertisement

hdavis is online now  


Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes Rate This Thread
Rate This Thread:

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off


Similar Threads
Thread Thread Starter Forum Replies Last Post
Cleaning a Limestone Office Building SRS-NY Pressure Washing 4 03-12-2014 07:54 AM
Faulty Masonry construction at Moore School cdkyle Masonry 6 02-24-2014 12:46 PM
backfill in a building suggestions? Below grade trench's jadleybray Commercial Construction 11 05-31-2012 03:55 PM
Block building leaking inside? GSS Masonry 9 05-24-2010 10:20 AM

Join Now... It's Fast and FREE!

I am a professional contractor
I am a DIY Homeowner
Drywall Talk is for
PROFESSIONAL CONTRACTORS ONLY!

At DrywallTalk.com we cater exlusivly to professional contractors who make their living as a contractor. Knowing that many homeowners and DIYers are looking for a community to call home, we've created www.DIYChatroom.com DIY Chatroom is full of helpful advices and perfect for DIY homeowners.

Redirecing in 10 seconds
No Thanks
terms of service

Already Have an Account?